Robot-Assisted Transarterial Chemoembolization of Hepatocellular Carcinoma Using a Coaxial Microcatheter Driving Controller-Responder Robot System: Clinical Pilot Study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Dong Kyu | - |
dc.contributor.author | Woo, Jaehong | - |
dc.contributor.author | Yi, Byung-Ju | - |
dc.contributor.author | Song, Hwa-Seob | - |
dc.contributor.author | Kim, Gyoung Min | - |
dc.contributor.author | Kwon, Joon Ho | - |
dc.contributor.author | Han, Kichang | - |
dc.contributor.author | Won, Jong Yun | - |
dc.date.accessioned | 2023-12-08T09:33:53Z | - |
dc.date.available | 2023-12-08T09:33:53Z | - |
dc.date.issued | 2023-09 | - |
dc.identifier.issn | 1051-0443 | - |
dc.identifier.issn | 1535-7732 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/115982 | - |
dc.description.abstract | Purpose: To evaluate the feasibility and safety of robot-assisted transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using a new coaxial microcatheter driving controller-responder robot (CRR) system. Materials and Methods: A single-center prospective pilot study approved by the institutional review board was conducted using this CRR developed after analyzing 20 cases of conventional TACE procedures from May to October 2021. The study included 10 patients with HCCs: 5 (median age, 72 years; range, 64-73 years) underwent robot-assisted TACE, and 5 (median age, 57 years; range, 44-76 years) underwent conventional TACE for comparison. The feasibility and safety of robot-assisted TACE were evaluated by assessing the technical success, procedure time, adverse event rate, radiation dose, and early tumor response. Results: The entire TACE procedure was divided into 30 steps, of which 8 could be robotized. In robot-assisted TACE, technical success was achieved in 4 (80%) of 5 patients. No procedure-related adverse event was observed. The median procedure time was 56 minutes. At the 1-month follow-up, 3 of the 4 patients showed a complete or partial response after robot-assisted TACE. The median radiation doses for the operator and patients were 0.4 and 2,167.5 mu Sv in robot-assisted TACE and 53.2 and 2,989.7 mu Sv in conventional TACE, respectively. Conclusions: Robot-assisted TACE using a new CRR system was feasible and safe for the treatment of HCC and could remarkably decrease radiation exposure for the operators. | - |
dc.format.extent | 10 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Lippincott Williams & Wilkins Ltd. | - |
dc.title | Robot-Assisted Transarterial Chemoembolization of Hepatocellular Carcinoma Using a Coaxial Microcatheter Driving Controller-Responder Robot System: Clinical Pilot Study | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1016/j.jvir.2023.06.004 | - |
dc.identifier.scopusid | 2-s2.0-85166304469 | - |
dc.identifier.wosid | 001070499000001 | - |
dc.identifier.bibliographicCitation | Journal of Vascular and Interventional Radiology, v.34, no.9, pp 1565 - 1574 | - |
dc.citation.title | Journal of Vascular and Interventional Radiology | - |
dc.citation.volume | 34 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 1565 | - |
dc.citation.endPage | 1574 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalResearchArea | Cardiovascular System & Cardiology | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Peripheral Vascular Disease | - |
dc.subject.keywordPlus | PERCUTANEOUS CORONARY INTERVENTION | - |
dc.subject.keywordPlus | FEASIBILITY | - |
dc.subject.keywordPlus | SAFETY | - |
dc.subject.keywordPlus | CATHETER | - |
dc.identifier.url | https://www.clinicalkey.com/#!/content/playContent/1-s2.0-S1051044323004153?returnurl=null&referrer=null | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.