Polymerization shrinkage distribution of during dental restoration observed by digital image correlation method
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, J.H. | - |
dc.contributor.author | Choi, N.S. | - |
dc.date.accessioned | 2021-06-22T15:23:18Z | - |
dc.date.available | 2021-06-22T15:23:18Z | - |
dc.date.issued | 2017-08 | - |
dc.identifier.issn | 0000-0000 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/11619 | - |
dc.description.abstract | Polymerization shrinkage distribution of composite resins during dental restoration was measured using digital image correlation method. Camera images were monitored during and after the light irradiation. Radial shrinkage strain was to be averagely 0.27% for AP-X and 0.12% for P90 over the whole resin area. Calculated strain results by finite element analysis were lower by 8% ~ 26% than experimental values obtained by digital image correlation. The shrinkage strain occurred much larger in the center part of the resin than in the resin/substrate interface region. The average radial strain of resins on the resin/substrate interface rapidly shrank within 4 minutes, and then converged to a constant value with an increase of time. © 2017 International Committee on Composite Materials. All rights reserved. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | International Committee on Composite Materials | - |
dc.title | Polymerization shrinkage distribution of during dental restoration observed by digital image correlation method | - |
dc.type | Article | - |
dc.identifier.scopusid | 2-s2.0-85053164702 | - |
dc.identifier.bibliographicCitation | ICCM International Conferences on Composite Materials, v.2017-August | - |
dc.citation.title | ICCM International Conferences on Composite Materials | - |
dc.citation.volume | 2017-August | - |
dc.type.docType | Conference Paper | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | Dental composite resin | - |
dc.subject.keywordAuthor | Digital image correlation | - |
dc.subject.keywordAuthor | Finite element | - |
dc.subject.keywordAuthor | Polymerization shrinkage | - |
dc.subject.keywordAuthor | Shrinkage distribution | - |
dc.identifier.url | https://www.iccm-central.org/Proceedings/ICCM21proceedings/ | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.