Impact of non-uniform wrinkles for a multi-stack pellicle in EUV lithography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, G.-J. | - |
dc.contributor.author | Kim, I.-S. | - |
dc.contributor.author | Yeung, M. | - |
dc.contributor.author | Kim, M.-S. | - |
dc.contributor.author | Park, J.-G. | - |
dc.contributor.author | Oh, H.-K. | - |
dc.date.accessioned | 2021-06-22T15:23:22Z | - |
dc.date.available | 2021-06-22T15:23:22Z | - |
dc.date.created | 2021-01-22 | - |
dc.date.issued | 2017-03 | - |
dc.identifier.issn | 0277-786X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/11622 | - |
dc.description.abstract | Extreme ultraviolet (EUV) pellicle is required for protecting the EUV mask from defects, contaminations, and particles during exposure process. EUV pellicle should be very thin for high transmission of EUV wavelength. Therefore, EUV pellicle can be easily deformed during the exposure process, and the multi-stack pellicle is suggested to minimize this deformation of EUV pellicle. The EUV multi-stack pellicle is made of polysilicon-based core layer and capping layers for the durability during the exposure process. Nevertheless, there remains other manufacturing, thermal, and mechanical problems. In this study, we investigated the impact of wrinkles of EUV pellicle, which can be formed during pellicle manufacturing or exposure process, in terms of transmission non-uniformity and critical dimension (CD) variation for 5- nm and 3-nm nodes. To fabricate 3-nm node, we need a high numerical aperture (NA) system such as an anamorphic NA system with chief ray angle of 6-degree. The wrinkle can be uniform in height and period, but we assumed a realistic non-uniform wrinkle. This non-uniform wrinkle of multi-stack pellicle may cause different image distortion for 5-nm and 3-nm nodes with the isomorphic and anamorphic NA systems. The transmission non-uniformity is calculated with various heights and periods of non-uniform wrinkles of the pellicle. It is found that the transmission non-uniformity for wrinkled pellicle for the anamorphic NA system can be larger than that for the isomorphic NA system to obtain CD uniformity below 0.2 nm. © 2017 SPIE. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | SPIE | - |
dc.title | Impact of non-uniform wrinkles for a multi-stack pellicle in EUV lithography | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Oh, H.-K. | - |
dc.identifier.doi | 10.1117/12.2258189 | - |
dc.identifier.scopusid | 2-s2.0-85020418196 | - |
dc.identifier.wosid | 000404910400057 | - |
dc.identifier.bibliographicCitation | Proceedings of SPIE - The International Society for Optical Engineering, v.10143 | - |
dc.relation.isPartOf | Proceedings of SPIE - The International Society for Optical Engineering | - |
dc.citation.title | Proceedings of SPIE - The International Society for Optical Engineering | - |
dc.citation.volume | 10143 | - |
dc.type.rims | ART | - |
dc.type.docType | Conference Paper | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | Deformation | - |
dc.subject.keywordPlus | Lithography | - |
dc.subject.keywordPlus | Manufacture | - |
dc.subject.keywordPlus | Masks | - |
dc.subject.keywordPlus | Critical dimension variations | - |
dc.subject.keywordPlus | EUV pellicle | - |
dc.subject.keywordPlus | Extreme ultraviolets | - |
dc.subject.keywordPlus | High numerical apertures | - |
dc.subject.keywordPlus | High transmission | - |
dc.subject.keywordPlus | Mechanical problems | - |
dc.subject.keywordPlus | Multi-stack pellicle | - |
dc.subject.keywordPlus | Wrinkled multi-stack pellicle | - |
dc.subject.keywordPlus | Extreme ultraviolet lithography | - |
dc.subject.keywordAuthor | EUV pellicle | - |
dc.subject.keywordAuthor | Multi-stack pellicle | - |
dc.subject.keywordAuthor | Pellicle deformation | - |
dc.subject.keywordAuthor | Wrinkled multi-stack pellicle | - |
dc.identifier.url | https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10143/1/Impact-of-non-uniform-wrinkles-for-a-multi-stack-pellicle/10.1117/12.2258189.short | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.