Comparing the mechanical stability of the pellicle under mask stage acceleration with different defect conditions
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeon, Ji-Hyun | - |
dc.contributor.author | Kang, Ji-Won | - |
dc.contributor.author | Oh, Hye-Keun | - |
dc.date.accessioned | 2024-01-15T01:30:24Z | - |
dc.date.available | 2024-01-15T01:30:24Z | - |
dc.date.issued | 2023-11 | - |
dc.identifier.issn | 0277-786X | - |
dc.identifier.issn | 1996-756X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/117745 | - |
dc.description.abstract | In the scanner, various forces act on the EUV pellicle. Identifying the underlying causes of pellicle destruction is challenging, and the criteria for evaluating the lifetime of the pellicle are ambiguous. Therefore, it is essential to analyze the complex forces that affect the pellicle and investigate how they impact its durability. Particle defects, in particular, can significantly reduce the lifetime of the pellicle, leading to mechanical damage such as deformation or destruction. To investigate these effects, we examined how particle defects impact the pellicle in the scanner environment, classifying them based on the type of defect. We modeled a scenario involving mask stage acceleration and compared the impact of defect conditions on pellicles, considering the increased scanner speed of a high-NA scanner. The results show that the stress around the defect increases rapidly due to the acceleration of the pellicle after being deflected by gravity. The embedded defect shows the highest stress, which has the potential to decrease the lifetime of the pellicle due to repeated acceleration. © 2023 SPIE. All rights reserved. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | SPIE | - |
dc.title | Comparing the mechanical stability of the pellicle under mask stage acceleration with different defect conditions | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1117/12.2687920 | - |
dc.identifier.scopusid | 2-s2.0-85179555790 | - |
dc.identifier.wosid | 001125089900038 | - |
dc.identifier.bibliographicCitation | Proceedings of SPIE - The International Society for Optical Engineering, v.12750, pp 1 - 7 | - |
dc.citation.title | Proceedings of SPIE - The International Society for Optical Engineering | - |
dc.citation.volume | 12750 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 7 | - |
dc.type.docType | Proceedings Paper | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.subject.keywordAuthor | EUV Pellicle | - |
dc.subject.keywordAuthor | High NA | - |
dc.subject.keywordAuthor | High volume manufacturing | - |
dc.subject.keywordAuthor | Mask stage acceleration | - |
dc.subject.keywordAuthor | Particle defect | - |
dc.subject.keywordAuthor | Pellicle acceleration | - |
dc.subject.keywordAuthor | Pellicle deflection | - |
dc.subject.keywordAuthor | Pellicle lifetime | - |
dc.identifier.url | https://www.spiedigitallibrary.org/conference-proceedings-of-spie/12750/2687920/Comparing-the-mechanical-stability-of-the-pellicle-under-mask-stage/10.1117/12.2687920.full#_=_ | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.