Comparing the mechanical stability of the pellicle under mask stage acceleration with different defect conditions

Full metadata record
DC Field Value Language
dc.contributor.authorJeon, Ji-Hyun-
dc.contributor.authorKang, Ji-Won-
dc.contributor.authorOh, Hye-Keun-
dc.date.accessioned2024-01-15T01:30:24Z-
dc.date.available2024-01-15T01:30:24Z-
dc.date.issued2023-11-
dc.identifier.issn0277-786X-
dc.identifier.issn1996-756X-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/117745-
dc.description.abstractIn the scanner, various forces act on the EUV pellicle. Identifying the underlying causes of pellicle destruction is challenging, and the criteria for evaluating the lifetime of the pellicle are ambiguous. Therefore, it is essential to analyze the complex forces that affect the pellicle and investigate how they impact its durability. Particle defects, in particular, can significantly reduce the lifetime of the pellicle, leading to mechanical damage such as deformation or destruction. To investigate these effects, we examined how particle defects impact the pellicle in the scanner environment, classifying them based on the type of defect. We modeled a scenario involving mask stage acceleration and compared the impact of defect conditions on pellicles, considering the increased scanner speed of a high-NA scanner. The results show that the stress around the defect increases rapidly due to the acceleration of the pellicle after being deflected by gravity. The embedded defect shows the highest stress, which has the potential to decrease the lifetime of the pellicle due to repeated acceleration. © 2023 SPIE. All rights reserved.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherSPIE-
dc.titleComparing the mechanical stability of the pellicle under mask stage acceleration with different defect conditions-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1117/12.2687920-
dc.identifier.scopusid2-s2.0-85179555790-
dc.identifier.wosid001125089900038-
dc.identifier.bibliographicCitationProceedings of SPIE - The International Society for Optical Engineering, v.12750, pp 1 - 7-
dc.citation.titleProceedings of SPIE - The International Society for Optical Engineering-
dc.citation.volume12750-
dc.citation.startPage1-
dc.citation.endPage7-
dc.type.docTypeProceedings Paper-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.subject.keywordAuthorEUV Pellicle-
dc.subject.keywordAuthorHigh NA-
dc.subject.keywordAuthorHigh volume manufacturing-
dc.subject.keywordAuthorMask stage acceleration-
dc.subject.keywordAuthorParticle defect-
dc.subject.keywordAuthorPellicle acceleration-
dc.subject.keywordAuthorPellicle deflection-
dc.subject.keywordAuthorPellicle lifetime-
dc.identifier.urlhttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/12750/2687920/Comparing-the-mechanical-stability-of-the-pellicle-under-mask-stage/10.1117/12.2687920.full#_=_-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY > DEPARTMENT OF APPLIED PHYSICS > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE