Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Model of High-Speed Endovascular Sonothrombolysis with Vortex Ultrasound-Induced Shear Stress to Treat Cerebral Venous Sinus Thrombosis

Full metadata record
DC Field Value Language
dc.contributor.authorZhang, Bohua-
dc.contributor.authorWu, Huaiyu-
dc.contributor.authorKim, Howuk-
dc.contributor.authorWelch, Phoebe J.-
dc.contributor.authorCornett, Ashley-
dc.contributor.authorStocker, Greyson-
dc.contributor.authorNogueira, Raul G.-
dc.contributor.authorKim, Jinwook-
dc.contributor.authorOwens, Gabe-
dc.contributor.authorDayton, Paul A.-
dc.contributor.authorXu, Zhen-
dc.contributor.authorShi, Chengzhi-
dc.contributor.authorJiang, Xiaoning-
dc.date.accessioned2024-01-18T07:00:26Z-
dc.date.available2024-01-18T07:00:26Z-
dc.date.issued2023-02-
dc.identifier.issn2096-5168-
dc.identifier.issn2639-5274-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/117763-
dc.description.abstractThis research aims to demonstrate a novel vortex ultrasound enabled endovascular thrombolysis method designed for treating cerebral venous sinus thrombosis (CVST). This is a topic of substantial importance since current treatment modalities for CVST still fail in as many as 20% to 40% of the cases, and the incidence of CVST has increased since the outbreak of the coronavirus disease 2019 pandemic. Compared with conventional anticoagulant or thrombolytic drugs, sonothrombolysis has the potential to remarkably shorten the required treatment time owing to the direct clot targeting with acoustic waves. However, previously reported strategies for sonothrombolysis have not demonstrated clinically meaningful outcomes (e.g., recanalization within 30 min) in treating large, completely occluded veins or arteries. Here, we demonstrated a new vortex ultrasound technique for endovascular sonothrombolysis utilizing wave-matter interaction-induced shear stress to enhance the lytic rate substantially. Our in vitro experiment showed that the lytic rate was increased by at least 64.3% compared with the nonvortex endovascular ultrasound treatment. A 3.1-g, 7.5-cm-long, completely occluded in vitro 3-dimensional model of acute CVST was fully recanalized within 8 min with a record-high lytic rate of 237.5 mg/min for acute bovine clot in vitro. Furthermore, we confirmed that the vortex ultrasound causes no vessel wall damage over ex vivo canine veins. This vortex ultrasound thrombolysis technique potentially presents a new life-saving tool for severe CVST cases that cannot be efficaciously treated using existing therapies. © 2023 Bohua Zhang et al.-
dc.format.extent13-
dc.language영어-
dc.language.isoENG-
dc.publisherAmerican Association for the Advancement of Science-
dc.titleA Model of High-Speed Endovascular Sonothrombolysis with Vortex Ultrasound-Induced Shear Stress to Treat Cerebral Venous Sinus Thrombosis-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.34133/research.004-
dc.identifier.scopusid2-s2.0-85152207991-
dc.identifier.wosid000992018200001-
dc.identifier.bibliographicCitationResearch, v.6, pp 1 - 13-
dc.citation.titleResearch-
dc.citation.volume6-
dc.citation.startPage1-
dc.citation.endPage13-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusTISSUE-PLASMINOGEN ACTIVATOR-
dc.subject.keywordPlusIN-VITRO-
dc.subject.keywordPlusACCELERATED CATHETER-
dc.subject.keywordPlusPULMONARY-EMBOLISM-
dc.subject.keywordPlusISCHEMIC-STROKE-
dc.subject.keywordPlusTHROMBOLYSIS-
dc.subject.keywordPlusDISSOLUTION-
dc.subject.keywordPlusTRANSDUCER-
dc.subject.keywordPlusFIBRIN-
dc.subject.keywordPlusSAFETY-
dc.identifier.urlhttps://spj.science.org/doi/10.34133/research.0048-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE