Suppression of saturation artifacts in swept source optical coherence tomography using dual channel detection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Li, Xinyu | - |
dc.contributor.author | Liang, Shanshan | - |
dc.contributor.author | Zhang, Jun | - |
dc.date.accessioned | 2024-04-09T03:01:51Z | - |
dc.date.available | 2024-04-09T03:01:51Z | - |
dc.date.issued | 2016-02 | - |
dc.identifier.issn | 0277-786X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/118565 | - |
dc.description.abstract | A technique to suppress saturation artifacts in swept source optical coherence tomography (SSOCT) system was presented. The detected signal was split into two channels of a high speed data acquisition card with two levels by a power divider. The signal in one channel with higher level was used to reconstruct OCT images and the signal in the other channel with lower level was used to compensate the saturated signal in the first channel by calibrating the splitting ratio between the two channels. Based on dual channel detection, this technique can enhance the dynamic range of SSOCT system and remove saturation artifacts in OCT imaging with simple and cost effective design. Imaging of human finger with the system demonstrated that this method can achieve high dynamic range without saturation artifacts in SSOCT. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | SPIE | - |
dc.title | Suppression of saturation artifacts in swept source optical coherence tomography using dual channel detection | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1117/12.2213794 | - |
dc.identifier.scopusid | 2-s2.0-84973401308 | - |
dc.identifier.wosid | 000378122900070 | - |
dc.identifier.bibliographicCitation | Proceedings of SPIE - The International Society for Optical Engineering, v.9697, pp 1 - 6 | - |
dc.citation.title | Proceedings of SPIE - The International Society for Optical Engineering | - |
dc.citation.volume | 9697 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 6 | - |
dc.type.docType | Proceedings Paper | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordAuthor | Optical Coherence Tomography | - |
dc.subject.keywordAuthor | high dynamic range | - |
dc.subject.keywordAuthor | saturation correction | - |
dc.subject.keywordAuthor | dual level detection | - |
dc.identifier.url | https://www.spiedigitallibrary.org/conference-proceedings-of-spie/9697/1/Suppression-of-saturation-artifacts-in-swept-source-optical-coherence-tomography/10.1117/12.2213794.full | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.