Real-Time Fluorescence Screening Platform for Meat Freshness
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ye, Huan | - |
dc.contributor.author | Koo, Seyoung | - |
dc.contributor.author | Zhu, Beitong | - |
dc.contributor.author | Ke, Yingjun | - |
dc.contributor.author | Sheng, Ruilong | - |
dc.contributor.author | Duan, Ting | - |
dc.contributor.author | Zeng, Lintao | - |
dc.contributor.author | Kim, Seung | - |
dc.date.accessioned | 2024-04-09T03:30:40Z | - |
dc.date.available | 2024-04-09T03:30:40Z | - |
dc.date.issued | 2022-10 | - |
dc.identifier.issn | 0003-2700 | - |
dc.identifier.issn | 1520-6882 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/118627 | - |
dc.description.abstract | Meat's freshness is closely related to food safety and human health and has received increasing attention nowadays. To on-site visually screen meat freshness in a fast and non-destructive manner, we rationally constructed a series of fluorescent probes (JDCN, JDNS, and JDPY) with distinct electron-withdrawing substitution groups based on julolidine-fused coumarin. These probes underwent an aza-Michael addition followed by an elimination reaction with cadaverine to generate a colorimetric and ratiometric fluorescence response, and their sensing performance was rationally enhanced by improving the electron-withdrawing strength of substitution groups. Particularly, JDCN with a dicyanovinyl group as the reaction site exhibited outstanding sensing performance including rapid response (similar to 60 s), high selectivity, and low detection limit (14 nM). Furthermore, JDCN was fabricated into test kits to detect cadaverine vapor with a high-contrast fluorescence change from red to green. Based on two-color visualization of cadaverine vapor, on-site non-contact and non-destructive monitoring of meat freshness was successfully achieved. The good sensing performance rendered JDCN test kits a promising real-time fluorescence screening platform for rapid, non-destructive, and accurate evaluation of meat freshness. | - |
dc.format.extent | 10 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | American Chemical Society | - |
dc.title | Real-Time Fluorescence Screening Platform for Meat Freshness | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1021/acs.analchem.2c03326 | - |
dc.identifier.scopusid | 2-s2.0-85141022860 | - |
dc.identifier.wosid | 000878472900001 | - |
dc.identifier.bibliographicCitation | Analytical Chemistry, v.94, no.44, pp 15423 - 15432 | - |
dc.citation.title | Analytical Chemistry | - |
dc.citation.volume | 94 | - |
dc.citation.number | 44 | - |
dc.citation.startPage | 15423 | - |
dc.citation.endPage | 15432 | - |
dc.type.docType | 정기학술지(Article(Perspective Article포함)) | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.subject.keywordPlus | BIOGENIC-AMINES | - |
dc.subject.keywordPlus | HYDROGEN-SULFIDE | - |
dc.subject.keywordPlus | PROBE | - |
dc.subject.keywordPlus | SENSOR | - |
dc.subject.keywordPlus | AGGREGATION | - |
dc.subject.keywordPlus | METABOLITES | - |
dc.subject.keywordPlus | DESIGN | - |
dc.identifier.url | https://pubs.acs.org/doi/10.1021/acs.analchem.2c03326 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.