Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Iridium oxide-based non-enzymatic glucose sensor: Superior electro-catalytic performance in biological environmental media

Full metadata record
DC Field Value Language
dc.contributor.authorJeon, Ji Hwan-
dc.contributor.authorLim, Hyo-Ryoung-
dc.contributor.authorPark, Ji Young-
dc.contributor.authorChoa, Yong-Ho-
dc.date.accessioned2024-04-23T06:00:41Z-
dc.date.available2024-04-23T06:00:41Z-
dc.date.issued2024-07-
dc.identifier.issn0013-9351-
dc.identifier.issn1096-0953-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/118853-
dc.description.abstractNanostructured inorganic materials have potential advantages as glucose-sensing elements in diabetes care, thereby circumventing the need for expensive enzymatic agents. However, many nonenzymatic sensors face challenges related to selectivity and reliability, reducing their efficacy in body fluids. In this study, we introduce an Iridium oxide (IrO2)-based non-enzymatic glucose sensor. This sensor demonstrates exceptional electro-catalytic properties in human serum, characterized by high sensitivity (638 μA μM−1cm2) and a consistent recovery rate (∼104%) across 15 cycles in saline. Furthermore, its impressive performance in human serum, as evidenced by a low relative standard deviation (RSD <1.57%), underscores its applicability in biological matrices such as interstitial fluids. Overall, the IrO2 sensor is a promising, highly reversible, economical, and simple method for detecting glucose in continuous monitoring systems. © 2024 Elsevier Inc.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherAcademic Press Inc.-
dc.titleIridium oxide-based non-enzymatic glucose sensor: Superior electro-catalytic performance in biological environmental media-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.envres.2024.118772-
dc.identifier.scopusid2-s2.0-85190496309-
dc.identifier.bibliographicCitationEnvironmental Research, v.252, pp 1 - 8-
dc.citation.titleEnvironmental Research-
dc.citation.volume252-
dc.citation.startPage1-
dc.citation.endPage8-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorHigh-selective electrochemical sensor-
dc.subject.keywordAuthorInorganic glucose sensor-
dc.subject.keywordAuthorIridium oxide-
dc.subject.keywordAuthorNon-enzymatic glucose sensor-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0013935124006765?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOA, YONG HO photo

CHOA, YONG HO
ERICA 공학대학 (DEPARTMENT OF MATERIALS SCIENCE AND CHEMICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE