High-Performance Electrochemical Creatinine Sensors Based on β-Lead Dioxide/Single-Walled Carbon Nanotube Electrodesopen access
- Authors
- Jeon, Sung Min; Lee, Han Been; Ha, Chang Hyeon; Kim, Do Hyeon; Li, Cheng Ai; Song, Sung Ho; Lee, Cheol-Jung; Han, Do Kyoung; Seong, Gi Hun
- Issue Date
- Oct-2024
- Publisher
- American Chemical Society
- Citation
- Analytical Chemistry, v.96, no.40, pp 15941 - 15949
- Pages
- 9
- Indexed
- SCIE
SCOPUS
- Journal Title
- Analytical Chemistry
- Volume
- 96
- Number
- 40
- Start Page
- 15941
- End Page
- 15949
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/120700
- DOI
- 10.1021/acs.analchem.4c02985
- ISSN
- 0003-2700
1520-6882
- Abstract
- Creatinine is an important biomarker of kidney function and muscular metabolism. In this paper, we developed the β-lead dioxide/single-walled carbon nanotube (β-PbO2/CNT) and the β-PbO2/CNT ion-selective electrode (β-PbO2/CNT/ISE), which were used as highly sensitive potentiometric sensors for creatinine detection. The fabricated electrodes exhibited highly pH-sensitive characteristics due to the synergistic effect of the electrochemical properties of CNT and β-PbO2. Moreover, an ammonium-ion-selective membrane coating allowed the β-PbO2/CNT electrode to be NH4+-selective for direct detection of the ammonium ion. By exploiting the electrochemical characteristics of these electrodes, the creatinine assay was established through the one-step selective conversion of creatinine by creatinine deiminase, in which the OH- and NH4+ generated by the enzymatic reaction were detected using β-PbO2/CNT and β-PbO2/CNT/ISE electrodes as pH- and NH4+-responsive sensors, respectively. The total creatinine assay can be completed within ∼5 min. The assay results from β-PbO2/CNT and β-PbO2/CNT/ISE showed excellent sensitivity values of −75.56 and 64.62 mV in the detection range of 10-400 μM with a fast response (20 s), and the limits of detection were calculated to be 0.06 and 0.13 μM, respectively. Moreover, the developed creatinine sensor showed high selectivity against 11 interfering bio/chemical species with negligible interferences (selectivity coefficient <10-4) and excellent repeatability (>97% within 25 cycles) and long-term stability for 4 weeks of storage. In addition, the feasibility and practicality of the device were successfully demonstrated in human serum tests, with recoveries of 95-104% for PbO2/CNT and 92-110% for PbO2/CNT/ISE. © 2024 The Authors. Published by American Chemical Society.
- Files in This Item
-
Go to Link
- Appears in
Collections - COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.