Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

BO-CLAHE enhancing neonatal chest X-ray image quality for improved lesion classificationopen access

Authors
이연준
Issue Date
Feb-2025
Publisher
NATURE PORTFOLIO
Keywords
Preterm; High-risk neonates; Neonatal chest X-ray; CLAHE; Bayesian optimization
Citation
SCIENTIFIC REPORTS, v.15, no.4931, pp 1 - 16
Pages
16
Indexed
SCIE
SCOPUS
Journal Title
SCIENTIFIC REPORTS
Volume
15
Number
4931
Start Page
1
End Page
16
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/122178
DOI
10.1038/s41598-025-88451-0
ISSN
2045-2322
2045-2322
Abstract
In the case of neonates, especially low birth weight preterm and high-risk infants, portable X-rays are frequently used. However, the image quality of portable X-rays is significantly lower compared to standard adult or pediatric X-rays, leading to considerable challenges in identifying abnormalities. Although attempts have been made to introduce deep learning to address these image quality issues, the poor quality of the images themselves hinders the training of deep learning models, further emphasizing the need for image enhancement. Additionally, since neonates have a high cell division rate and are highly sensitive to radiation, increasing radiation exposure to improve image quality is not a viable solution. Therefore, it is crucial to enhance image quality through preprocessing before training deep learning models. While various image enhancement methods have been proposed, Contrast Limited Adaptive Histogram Equalization (CLAHE) has been recognized as an effective technique for contrast-based image improvement. However, despite extensive research, the process of setting CLAHE’s hyperparameters still relies on a brute force, manual approach, making it inefficient. To address this issue, we propose a method called Bayesian Optimization CLAHE(BO-CLAHE), which leverages Bayesian optimization to automatically select the optimal hyperparameters for X-ray images used in diagnosing lung diseases in preterm and high-risk neonates. The images enhanced by BO-CLAHE demonstrated superior performance across several classification models, with particularly notable improvements in diagnosing Transient Tachypnea of the Newborn (TTN). This approach not only reduces radiation exposure but also contributes to the development of AI-based diagnostic tools, playing a crucial role in the early diagnosis and treatment of preterm and high-risk neonates.
Files in This Item
There are no files associated with this item.
Appears in
Collections
COLLEGE OF COMPUTING > ERICA 컴퓨터학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Yeon joon photo

Lee, Yeon joon
ERICA 소프트웨어융합대학 (ERICA 컴퓨터학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE