Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Transdermal transport efficiency during skin electroporation and iontophoresis

Full metadata record
DC Field Value Language
dc.contributor.authorPrausnitz, Mark R.-
dc.contributor.authorLee, Caroline Sunyong-
dc.contributor.authorLiu, Cindy H.-
dc.contributor.authorPang, Judy C.-
dc.contributor.authorSingh, Tej-Preet-
dc.contributor.authorLanger, Robert-
dc.contributor.authorWeaver, James C.-
dc.date.accessioned2025-04-24T02:02:01Z-
dc.date.available2025-04-24T02:02:01Z-
dc.date.issued1996-02-
dc.identifier.issn0168-3659-
dc.identifier.issn1873-4995-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/125142-
dc.description.abstractHigh-voltage pulsing has previously been shown to dramatically increase molecular transport across skin. The goal of this study was to examine the functional dependence of transdermal transport on pulse parameters and to make comparisons with iontophoresis. Transdermal transport of calcein, a model drug, was measured during low-voltage, constant electric fields (iontophoresis) and high-voltage pulsed electric fields (hypothesized to cause electroporation). In the first part of the study, the dependence of calcein flux caused by high-voltage pulses was determined as a function of pulse length, rate, polarity, waveform, and total pulsing time. In the second part, calcein transport numbers were calculated for both iontophoresis and high-voltage pulsing, and expressed as functions of pulse parameters. For both iontophoresis and high-voltage pulsing, transport numbers (or transport efficiency) ranged from 10−5 to 10−2 and were functions of voltage and current, but did not show dependence on pulse length, rate, energy, waveform, or total charge transferred. The resulting estimates of the area fraction of skin available to transport were larger during high-voltage pulsing ( 10−3 for small ions and 10−6 to 10−3 for calcein) than during iontophoresis (10−5 to 10−4 for small ions and 10−8 to 10−4 for calcein).-
dc.format.extent13-
dc.publisherElsevier BV-
dc.titleTransdermal transport efficiency during skin electroporation and iontophoresis-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/0168-3659(95)00121-2-
dc.identifier.bibliographicCitationJournal of Controlled Release, v.38, no.2-3, pp 205 - 217-
dc.citation.titleJournal of Controlled Release-
dc.citation.volume38-
dc.citation.number2-3-
dc.citation.startPage205-
dc.citation.endPage217-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorElectroporationIontophoresisTransdermal drug deliveryTransport numberTransport pathway-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sunyong Caroline photo

Lee, Sunyong Caroline
ERICA 첨단융합대학 (ERICA 신소재·반도체공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE