Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of Hybrid Corrosion Inhibitor on Mechanical Characteristics, Corrosion Behavior, and Predictive Estimation of Lifespan of Reinforced Concrete Structuresopen access

Authors
Tran, Duc ThanhLee, Han-SeungSingh, Jitendra KumarYang, Hyun-MinJeong, Min-GuYan, SiruiIbrahim, Izni SyahrizalAriffin, Mohd Azreen Bin MohdLe, Anh-TuanSingh, Anjani Kumar
Issue Date
Mar-2025
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
Keywords
carbon steel; electrochemical studies; hybrid corrosion inhibitor; mechanical studies; reinforced concrete; service life predictions
Citation
Buildings, v.15, no.7, pp 1 - 6
Pages
6
Indexed
SCIE
SCOPUS
Journal Title
Buildings
Volume
15
Number
7
Start Page
1
End Page
6
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/125298
DOI
10.3390/buildings15071114
ISSN
2075-5309
2075-5309
Abstract
A fixed ratio amount, i.e., L-arginine (LA) and trisodium phosphate dodecahydrate (TSP) at 2:0.25, is considered as a hybrid inhibitor. This research aims to extensively investigate the impact of utilizing the hybrid corrosion inhibitor on the corrosion resistance properties in accelerated condition, mechanical characteristics, and predictive estimation of the lifespan of reinforced concrete (RC) structures. Various experiments, such as setting time, slump, air content, porosity, compressive strength, and chloride diffusion coefficient, were conducted to elucidate the influence of the hybrid corrosion inhibitor on the mechanical properties of the concrete matrix. Meanwhile, linear polarization resistance (LPR) and electrochemical impedance spectroscopy (EIS) in 10 wt. % NaCl under wet–dry cycles are utilized to assess the corrosion resistance property, corrosion initiation time, and kinetics of the passive film formation on the steel rebar. Alternatively, both deterministic and probabilistic-based predictions of service life by Life 365 software are utilized to demonstrate the efficacy of the hybrid corrosion inhibitor in protecting the steel rebar in RC structures. All the results confirm that the HI-4 mix (LA:TSP = 3.56:0.44) exhibits excellence in preventing the corrosion and extending the service life of RC structures, due to the adsorption of inhibitor molecules and formation of P-Zwitterions-(Cl)-Fe, Zwitterions-(Cl)-Fe, and FePO4 complexes onto the steel rebar surface. However, HI-3 shows the optimal mechanical and electrochemical properties for RC structures. © 2025 by the authors.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > ERICA 지속가능건축융합전공 > 1. Journal Articles
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher HYUNMIN, YANG photo

HYUNMIN, YANG
ERICA 공학대학 (ERICA 지속가능건축융합전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE