Chitosan-stabilized Prussian blue nanoparticle-based multi-mode readout colorimetric, fluorometric, and photothermal biosensor for sensitive uric acid detection

Authors
Kim, Do HyeonLee, Han BeenHa, Chang HyeonJeon, Sung MinSeong, Gi Hun
Issue Date
Aug-2025
Publisher
Elsevier Inc.
Keywords
Colorimetric; Fluorometric; Multi-mode readout; Nanozyme; Photothermal effect; Uric acid
Citation
Microchemical Journal, v.215, pp 1 - 10
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
Microchemical Journal
Volume
215
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/126140
DOI
10.1016/j.microc.2025.114486
ISSN
0026-265X
1095-9149
Abstract
Abnormal levels of uric acid (UA) indicate warning signals for gout and metabolic cardiovascular diseases, requiring the monitoring of UA levels for early diagnosis and prevention. Nevertheless, most of the detection methods for uric acid (UA) rely on a single-mode readout, which is susceptible to a multitude of variables, resulting in inaccurate outcomes. To overcome the above limitations, in this study, we employed chitosan-stabilized Prussian blue nanoparticles (CS@PBNPs), which provide a strategy for a colorimetric, photothermal, and fluorometric multi-mode detection of UA. The CS@PBNPs exhibited excellent peroxidase-like activity, and chitosan, as a stabilizer, notably enhanced both colloidal dispersion and stability. In the presence of hydrogen peroxide, produced by enzymatic reaction, CS@PBNPs oxidize 3,3′,5,5′-tetramethylbenzidine (TMB) and o-phenylenediamine (OPD). Oxidized TMB showed a blue color with a photothermal effect at near-infrared (NIR) regions and was employed as a probe for colorimetric and photothermal detection. Oxidized OPD, which exhibits yellow color and fluorescence, served as a probe for both colorimetric and fluorescent detection. The multi-mode readout sensor demonstrated a broad linear detection range of 0–1000 μM, with limits of detection (LOD) of 1.93 μM (colorimetric), 5.01 μM (fluorometric), and 8.90 μM (photothermal), enhancing the detection range (10–800 μM) and LOD (10 μM) of conventional single-mode readout. Moreover, each method exhibited excellent reliabilty and reproducibility in detection of UA in human serum samples, indicating the suitability in practical applications. Consequently, CS@PBNP-based multi-mode sensing platform provided detection results in different output modes, significant enhancement of assay accuracy. © 2025 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 첨단융합대학 (ERICA 바이오나노공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE