Shape and Contact Force Estimation of Inserted Flexible Medical Device

Full metadata record
DC Field Value Language
dc.contributor.authorRyu, Hwan-Taek-
dc.contributor.authorWoo, Jaehong-
dc.contributor.authorSo, Byung-Rok-
dc.contributor.authorYi, Byung-Ju-
dc.date.accessioned2021-06-22T09:08:53Z-
dc.date.available2021-06-22T09:08:53Z-
dc.date.issued2020-01-
dc.identifier.issn1598-6446-
dc.identifier.issn2005-4092-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/1385-
dc.description.abstractFlexible devices such as colonoscopy tube or catheter being inserted into the human-body make contact with the human tissues at several locations. Excessive contact force may damage the human tissues. To cope with this problem, the first aim of this paper is the shape estimation of the flexible body inside the human body using only two electromagnetic sensors. For this, the flexible body is modeled as kinematically redundant manipulator with many joints and links. The second aim is to estimate contact forces at a point, line contact, and multiple points. Cosserat-rod theory is employed to solve this problem. The effectiveness of the proposed algorithms is proved through both experiment and simulation for a flexible colonoscopy tube.-
dc.format.extent12-
dc.language영어-
dc.language.isoENG-
dc.publisher제어·로봇·시스템학회-
dc.titleShape and Contact Force Estimation of Inserted Flexible Medical Device-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1007/s12555-019-0237-8-
dc.identifier.scopusid2-s2.0-85075916686-
dc.identifier.wosid000499682800001-
dc.identifier.bibliographicCitationInternational Journal of Control, Automation, and Systems, v.18, no.1, pp 163 - 174-
dc.citation.titleInternational Journal of Control, Automation, and Systems-
dc.citation.volume18-
dc.citation.number1-
dc.citation.startPage163-
dc.citation.endPage174-
dc.type.docTypeArticle-
dc.identifier.kciidART002543392-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaAutomation & Control Systems-
dc.relation.journalWebOfScienceCategoryAutomation & Control Systems-
dc.subject.keywordPlusROBOT-
dc.subject.keywordAuthorCosserat-rod theory-
dc.subject.keywordAuthorflexible colonoscope-
dc.subject.keywordAuthorkinematically redundancy-
dc.subject.keywordAuthormultiple contact force estimation-
dc.subject.keywordAuthorshape estimation-
dc.identifier.urlhttps://link.springer.com/article/10.1007/s12555-019-0237-8-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yi, Byung Ju photo

Yi, Byung Ju
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE