Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fabrication of flexible, transparent silver nanowire electrodes for amperometric detection of hydrogen peroxide

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Joo Heon-
dc.contributor.authorLee, Heon-
dc.contributor.authorHuynh-Nguyen, Buu-Chau-
dc.contributor.authorKo, Euna-
dc.contributor.authorKim, Ji Hye-
dc.contributor.authorSeong, Gi Hun-
dc.date.accessioned2021-06-22T17:04:41Z-
dc.date.available2021-06-22T17:04:41Z-
dc.date.issued2016-03-
dc.identifier.issn0925-4005-
dc.identifier.issn0925-4005-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/14167-
dc.description.abstractWe present a simple method to fabricate flexible, transparent silver nanowire (AgNW) films. Homogenous AgNW networks were formed on a mixed cellulose ester (MCE) membrane by vacuum filtration and were easily transferable to self-adhesive poly(ethylene terephthalate). The opaque, white MCE membrane became transparent after being subjected to hot acetone vapor. The fabricated AgNW films had an average resistivity of 13 Omega/sq and a transmittance of approximately 67%. Moreover, the AgNW films showed excellent mechanical properties in repeated adhesion tests and bending tests. The AgNW films also showed good resistance against heat and NaC1 solutions. AgNW films were patterned by a combination of soft lithography and a solution-based chemical etching technique. The area under the photoresist polymer maintained its conductivity and transmittance after etching, whereas increased resistance and transparency were observed in the etched area. The suitability of the patterned AgNW electrodes for electronic devices was demonstrated via a simple LED chip array. After using standard photolithography to define the working area, AgNW films were used as sensor electrodes for the electrochemical detection of hydrogen peroxide (H2O2). The AgNW sensors displayed a reasonable detection limit of 46 p,M (SIN = 3), a rapid response time (within 2 s), and high sensitivity (749 mu AmM-1 cm(-2) and 1640 mu AmM-1 cm(-2)). Furthermore, the AgNW sensor was resistant to other potential interfering electroactive species commonly present in physiological samples such as L-ascorbic acid, glucose, and sodium oxalate. These results indicate that the AgNW sensor is selective for electroreduction of H2O2. Additionally, the developed sensor exhibited a stable amperometric response to the reduction of H2O2 even after extended storage. (C) 2015 Elsevier B.V. All rights reserved.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE SA-
dc.titleFabrication of flexible, transparent silver nanowire electrodes for amperometric detection of hydrogen peroxide-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.1016/j.snb.2015.11.006-
dc.identifier.scopusid2-s2.0-84946882338-
dc.identifier.wosid000366459500097-
dc.identifier.bibliographicCitationSENSORS AND ACTUATORS B-CHEMICAL, v.224, pp 789 - 797-
dc.citation.titleSENSORS AND ACTUATORS B-CHEMICAL-
dc.citation.volume224-
dc.citation.startPage789-
dc.citation.endPage797-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusCONDUCTIVE THIN-FILMS-
dc.subject.keywordPlusCARBON NANOTUBES-
dc.subject.keywordPlusSPRAY DEPOSITION-
dc.subject.keywordPlusPOLYMER-
dc.subject.keywordPlusENHANCEMENT-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusNETWORKS-
dc.subject.keywordPlusLASER-
dc.subject.keywordAuthorSilver nanowire-
dc.subject.keywordAuthorHydrogen peroxide-
dc.subject.keywordAuthorElectrochemical analysis-
dc.subject.keywordAuthorFlexible electrode-
dc.subject.keywordAuthorMicro-patterning-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0925400515305840?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 첨단융합대학 (ERICA 바이오나노공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE