Asymmetrical Fault Correction for the Sensitive Loads Using a Current Regulated Voltage Source Inverter
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bukhari, Syed Sabir Hussain | - |
dc.contributor.author | Atiq, Shahid | - |
dc.contributor.author | Lipo, Thomas A. | - |
dc.contributor.author | Kwon, Byung-il | - |
dc.date.accessioned | 2021-06-22T17:05:26Z | - |
dc.date.available | 2021-06-22T17:05:26Z | - |
dc.date.created | 2021-01-21 | - |
dc.date.issued | 2016-03 | - |
dc.identifier.issn | 1996-1073 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/14198 | - |
dc.description.abstract | Numerous industrial applications involve loads that are very sensitive to electrical supply instabilities. These instances involve various types of voltage imbalances as well as more serious disturbances such as symmetrical and asymmetrical faults. This paper proposes a cost-effective voltage imbalance and asymmetrical fault correction solution for the three phase sensitive loads utilizing an industry-standard current regulated voltage source inverter by connecting it in parallel to the grid mains powering to the sensitive load. The inverter regulates the current for the load and never permits it to go beyond a prescribed value under any type of asymmetrical fault condition, which ensures high power regulating and conditioning capacities. Experimental results are obtained from a small laboratory size prototype to validate the operation of the proposed technique. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.title | Asymmetrical Fault Correction for the Sensitive Loads Using a Current Regulated Voltage Source Inverter | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kwon, Byung-il | - |
dc.identifier.doi | 10.3390/en9030196 | - |
dc.identifier.scopusid | 2-s2.0-84962838937 | - |
dc.identifier.wosid | 000373625500104 | - |
dc.identifier.bibliographicCitation | ENERGIES, v.9, no.3, pp.1 - 14 | - |
dc.relation.isPartOf | ENERGIES | - |
dc.citation.title | ENERGIES | - |
dc.citation.volume | 9 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 14 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.subject.keywordPlus | POWER QUALITY | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordAuthor | current regulated inverter | - |
dc.subject.keywordAuthor | fault correction | - |
dc.subject.keywordAuthor | current regulation | - |
dc.subject.keywordAuthor | asymmetrical faults | - |
dc.identifier.url | https://www.mdpi.com/1996-1073/9/3/196 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.