Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Asymmetrical Fault Correction for the Sensitive Loads Using a Current Regulated Voltage Source Inverter

Full metadata record
DC Field Value Language
dc.contributor.authorBukhari, Syed Sabir Hussain-
dc.contributor.authorAtiq, Shahid-
dc.contributor.authorLipo, Thomas A.-
dc.contributor.authorKwon, Byung-il-
dc.date.accessioned2021-06-22T17:05:26Z-
dc.date.available2021-06-22T17:05:26Z-
dc.date.created2021-01-21-
dc.date.issued2016-03-
dc.identifier.issn1996-1073-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/14198-
dc.description.abstractNumerous industrial applications involve loads that are very sensitive to electrical supply instabilities. These instances involve various types of voltage imbalances as well as more serious disturbances such as symmetrical and asymmetrical faults. This paper proposes a cost-effective voltage imbalance and asymmetrical fault correction solution for the three phase sensitive loads utilizing an industry-standard current regulated voltage source inverter by connecting it in parallel to the grid mains powering to the sensitive load. The inverter regulates the current for the load and never permits it to go beyond a prescribed value under any type of asymmetrical fault condition, which ensures high power regulating and conditioning capacities. Experimental results are obtained from a small laboratory size prototype to validate the operation of the proposed technique.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.titleAsymmetrical Fault Correction for the Sensitive Loads Using a Current Regulated Voltage Source Inverter-
dc.typeArticle-
dc.contributor.affiliatedAuthorKwon, Byung-il-
dc.identifier.doi10.3390/en9030196-
dc.identifier.scopusid2-s2.0-84962838937-
dc.identifier.wosid000373625500104-
dc.identifier.bibliographicCitationENERGIES, v.9, no.3, pp.1 - 14-
dc.relation.isPartOfENERGIES-
dc.citation.titleENERGIES-
dc.citation.volume9-
dc.citation.number3-
dc.citation.startPage1-
dc.citation.endPage14-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusPOWER QUALITY-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthorcurrent regulated inverter-
dc.subject.keywordAuthorfault correction-
dc.subject.keywordAuthorcurrent regulation-
dc.subject.keywordAuthorasymmetrical faults-
dc.identifier.urlhttps://www.mdpi.com/1996-1073/9/3/196-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE