Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A robotic system for percutaneous coronary intervention equipped with a steerable catheter and force feedback function

Authors
Cha, H.Yoon, H.-S.Jung, K.Y.Yi, B.-J.Lee, S.Won, J.Y.
Issue Date
Oct-2016
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Catheters; Robots; Arteries; Gears; Actuators; Wires; Haptic interfaces
Citation
IEEE International Conference on Intelligent Robots and Systems, v.2016-November, pp.1151 - 1156
Indexed
SCIE
SCOPUS
Journal Title
IEEE International Conference on Intelligent Robots and Systems
Volume
2016-November
Start Page
1151
End Page
1156
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/15631
DOI
10.1109/IROS.2016.7759194
ISSN
2153-0858
Abstract
Purpose of this study is to propose a new robotic system equipped with a steerable catheter for percutaneous coronary intervention. Key design issues of the system are less X-ray exposure, easy sterilization, and convenient user interface. At first, vascular intervention procedure using the robotic system equipped with a steerable catheter are analyzed and compared with the conventional procedure. A two directional steerable catheter with minimum modification of a conventional catheter is developed. Robotic parts which contact the devices were designed to be easily separable from the slave robot for sterilization. Master robots are compactly and intuitively designed to conduct steering, insertion, and rotational motion. One master robot conducts steering of a catheter and the other master robot handles insertion and rotation of a catheter and a guidewire. The master-slave robotic system is evaluated using the phantom. During the phantom experiment, the contact force of the guidewire tip is measured and reflected to the user through the master robot. The system usability was evaluated with respect to task completion time, usefulness of the steerable catheter and haptic interface. It is confirmed through the experiments that the master-slave robotic system with steerable catheter is well designed to help user perform vascular intervention successfully and efficiently. © 2016 IEEE.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yi, Byung Ju photo

Yi, Byung Ju
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE