Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Real-time monitoring of geosmin based on an aptamer-conjugated graphene field-effect transistor

Full metadata record
DC Field Value Language
dc.contributor.authorPark,Seon-joo-
dc.contributor.authorSeo,Sung-eun-
dc.contributor.authorKim, Kyung-ho-
dc.contributor.authorLee, Sanghun-
dc.contributor.authorKim, Jinyeong-
dc.contributor.authorHa,Siyoung-
dc.contributor.authorSong, Hyun Seok-
dc.contributor.authorLee, Seung-hwan-
dc.contributor.authorKwon, Oh-seok-
dc.date.accessioned2021-06-22T09:15:54Z-
dc.date.available2021-06-22T09:15:54Z-
dc.date.created2021-01-22-
dc.date.issued2021-02-
dc.identifier.issn0956-5663-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/1783-
dc.description.abstractIn this paper, we propose a novel field-effect transistor (FET) using graphene, which is a two-dimensional (2D) nanomaterial, capable of evaluating water quality, and immobilizing the surface of a graphene micropatterned transistor with a highly responsive bioprobe for a water contamination indicator, geosmin, with high selectivity. A high-quality bioprobe-immobilized graphene FET (GFET) was fabricated for the real-time monitoring of geosmin using a liquid-gate measurement configuration. Immobilization was confirmed by measuring the change in the electrical characteristics of the platform (slope of the current-voltage (I–V) curve) and fluorescence images. In addition, a selectivity test showed remarkable implementation of the highly sensitive sensing platform with an insignificant signal when a nontarget was added. Using the fabricated device, the linear range for geosmin detection was determined to be from 0.01 nM - 1 μM with a detection limit of 0.01 nM. In addition, geosmin concentrations as low as 10 nM could be determined from river water samples with the sensor platform. This sensor can be utilized to immediately determine the presence of odorous substances by analyzing a water supply source without additional pretreatment. Another advantage is that the sensor device is a promising tool that does not have special equipment that requirs careful maintenance. In addition, the device provides a new platform for detecting harmful substances in various water sources by varying the bioprobes that are empolyed. © 2020 Elsevier B.V.-
dc.language영어-
dc.language.isoen-
dc.publisherElsevier Ltd-
dc.titleReal-time monitoring of geosmin based on an aptamer-conjugated graphene field-effect transistor-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Seung-hwan-
dc.identifier.doi10.1016/j.bios.2020.112804-
dc.identifier.scopusid2-s2.0-85096851999-
dc.identifier.wosid000605488400003-
dc.identifier.bibliographicCitationBiosensors and Bioelectronics, v.174, pp.1 - 8-
dc.relation.isPartOfBiosensors and Bioelectronics-
dc.citation.titleBiosensors and Bioelectronics-
dc.citation.volume174-
dc.citation.startPage1-
dc.citation.endPage8-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiophysics-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryBiophysics-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.subject.keywordPlusField effect transistors-
dc.subject.keywordPlusGraphene-
dc.subject.keywordPlusWater pollution-
dc.subject.keywordPlusWater quality-
dc.subject.keywordPlusWater supply-
dc.subject.keywordPlusElectrical characteristic-
dc.subject.keywordPlusGraphene fets (GFET)-
dc.subject.keywordPlusGraphene field-effect transistors-
dc.subject.keywordPlusMeasurement configuration-
dc.subject.keywordPlusReal time monitoring-
dc.subject.keywordPlusTwo Dimensional (2 D)-
dc.subject.keywordPlusWater contamination-
dc.subject.keywordPlusWater supply sources-
dc.subject.keywordPlusGraphene transistors-
dc.subject.keywordAuthorGeosmin-
dc.subject.keywordAuthorGraphene field-effect transistor-
dc.subject.keywordAuthorOdor compound-
dc.subject.keywordAuthorPortable nanobiosensor-
dc.subject.keywordAuthorReal-time monitoring-
dc.identifier.urlhttps://www.scopus.com/record/display.uri?eid=2-s2.0-85096851999&origin=inward&txGid=732335def458c19e7042578bdfdbbfa1-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher LEE, SEUNG HWAN photo

LEE, SEUNG HWAN
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE