An on-line UPS system that eliminates the inrush current phenomenon while feeding multiple load transformers
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bukhari, Syed sabir hussain | - |
dc.contributor.author | Lipo, Thomas A. | - |
dc.contributor.author | Kwon, Byung il | - |
dc.date.accessioned | 2021-06-22T21:43:24Z | - |
dc.date.available | 2021-06-22T21:43:24Z | - |
dc.date.created | 2021-01-22 | - |
dc.date.issued | 2015-06 | - |
dc.identifier.issn | 2150-6078 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/20615 | - |
dc.description.abstract | Numerous industrial facilities involve the installation of load transformers with their respective loads. As loads are turned on and off, these transformers are energized and de-energized, respectively, which can cause serious disturbances to sensitive loads. An inrush current, which typically occurs when a transformer is energized, can easily be observed using on-line uninterruptible power supply (UPS) systems feeding such loads. This paper proposes an on-line UPS system that eliminates the inrush current phenomenon caused by the energizing of load transformers. The UPS inverter specifically utilizes a fast acting current control scheme that enables it to regulate current for the load during all energizing conditions of load transformer connected to the UPS system. © 2015 Korean Institute of Power Electronics. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
dc.title | An on-line UPS system that eliminates the inrush current phenomenon while feeding multiple load transformers | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kwon, Byung il | - |
dc.identifier.doi | 10.1109/ICPE.2015.7167815 | - |
dc.identifier.scopusid | 2-s2.0-84959403438 | - |
dc.identifier.bibliographicCitation | 9th International Conference on Power Electronics - ECCE Asia: Green World with Power Electronics, ICPE 2015-ECCE Asia, v.2015, pp.385 - 390 | - |
dc.relation.isPartOf | 9th International Conference on Power Electronics - ECCE Asia: Green World with Power Electronics, ICPE 2015-ECCE Asia | - |
dc.citation.title | 9th International Conference on Power Electronics - ECCE Asia: Green World with Power Electronics, ICPE 2015-ECCE Asia | - |
dc.citation.volume | 2015 | - |
dc.citation.startPage | 385 | - |
dc.citation.endPage | 390 | - |
dc.type.rims | ART | - |
dc.type.docType | Conference Paper | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | current regulator | - |
dc.subject.keywordAuthor | Inrush current elimination | - |
dc.subject.keywordAuthor | mutilple load transformers | - |
dc.subject.keywordAuthor | on-line UPS systems | - |
dc.subject.keywordAuthor | voltage regulator | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/7167815 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.