Predictable and Reliable ECG Monitoring over IEEE 802.11 WLANs Within a Hospital
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Juyoung | - |
dc.contributor.author | Kang, Kyungtae | - |
dc.date.accessioned | 2021-06-22T22:44:13Z | - |
dc.date.available | 2021-06-22T22:44:13Z | - |
dc.date.created | 2021-01-21 | - |
dc.date.issued | 2014-09 | - |
dc.identifier.issn | 1530-5627 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/21982 | - |
dc.description.abstract | Telecardiology provides mobility for patients who require constant electrocardiogram (ECG) monitoring. However, its safety is dependent on the predictability and robustness of data delivery, which must overcome errors in the wireless channel through which the ECG data are transmitted. We report here a framework that can be used to gauge the applicability of IEEE 802.11 wireless local area network (WLAN) technology to ECG monitoring systems in terms of delay constraints and transmission reliability. For this purpose, a medical-grade WLAN architecture achieved predictable delay through the combination of a medium access control mechanism based on the point coordination function provided by IEEE 802.11 and an error control scheme based on Reed-Solomon coding and block interleaving. The size of the jitter buffer needed was determined by this architecture to avoid service dropout caused by buffer underrun, through analysis of variations in transmission delay. Finally, we assessed this architecture in terms of service latency and reliability by modeling the transmission of uncompressed two-lead electrocardiogram data from the MIT-BIH Arrhythmia Database and highlight the applicability of this wireless technology to telecardiology. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MARY ANN LIEBERT, INC | - |
dc.title | Predictable and Reliable ECG Monitoring over IEEE 802.11 WLANs Within a Hospital | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kang, Kyungtae | - |
dc.identifier.doi | 10.1089/tmj.2013.0263 | - |
dc.identifier.scopusid | 2-s2.0-84906897476 | - |
dc.identifier.wosid | 000341762300014 | - |
dc.identifier.bibliographicCitation | TELEMEDICINE AND E-HEALTH, v.20, no.9, pp.875 - 882 | - |
dc.relation.isPartOf | TELEMEDICINE AND E-HEALTH | - |
dc.citation.title | TELEMEDICINE AND E-HEALTH | - |
dc.citation.volume | 20 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 875 | - |
dc.citation.endPage | 882 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Health Care Sciences & Services | - |
dc.relation.journalWebOfScienceCategory | Health Care Sciences & Services | - |
dc.subject.keywordPlus | DATA-TRANSMISSION | - |
dc.subject.keywordPlus | WIRELESS SYSTEM | - |
dc.subject.keywordPlus | 2.4 GHZ | - |
dc.subject.keywordPlus | TECHNOLOGIES | - |
dc.subject.keywordPlus | QOS | - |
dc.subject.keywordAuthor | wireless electrocardiogram | - |
dc.subject.keywordAuthor | IEEE 802 | - |
dc.subject.keywordAuthor | 11 | - |
dc.subject.keywordAuthor | e-health | - |
dc.subject.keywordAuthor | predictability | - |
dc.subject.keywordAuthor | reliability | - |
dc.subject.keywordAuthor | cardiology | - |
dc.identifier.url | https://www.liebertpub.com/doi/10.1089/tmj.2013.0263 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.