Crack control design due to drying shrinkage in restrained reinforced concrete wall
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chung, Lan | - |
dc.contributor.author | Lee, Moon-Sung | - |
dc.contributor.author | Seo, Tae-Seok | - |
dc.date.accessioned | 2021-06-23T02:23:19Z | - |
dc.date.available | 2021-06-23T02:23:19Z | - |
dc.date.created | 2020-12-14 | - |
dc.date.issued | 2013-10 | - |
dc.identifier.issn | 1541-7794 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/26700 | - |
dc.description.abstract | This study considered the crack control design method of reinforced concrete wall subjected to uniaxial tension caused by drying shrinkage. From this study, a practical crack control design method of RC wall by controlling the restraint tensile strain caused by drying shrinkage was proposed. In addition, the validity of the proposed method was investigated by comparing with the experimental results (restraint ratio and restraint tensile strain) of small-scale RC wall specimens under the uniaxial restrained condition. In conclusion, there was good agreement between the values predicted by the proposed method and the experimental values. It is expected that the method proposed in this study enables quantitative crack control design through rational combinations between the materials and structural design. Copyright (c) 2011 John Wiley & Sons, Ltd. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | WILEY-BLACKWELL | - |
dc.title | Crack control design due to drying shrinkage in restrained reinforced concrete wall | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Moon-Sung | - |
dc.identifier.doi | 10.1002/tal.732 | - |
dc.identifier.scopusid | 2-s2.0-84884134368 | - |
dc.identifier.wosid | 000324100300002 | - |
dc.identifier.bibliographicCitation | STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, v.22, no.14, pp.1047 - 1061 | - |
dc.relation.isPartOf | STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS | - |
dc.citation.title | STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS | - |
dc.citation.volume | 22 | - |
dc.citation.number | 14 | - |
dc.citation.startPage | 1047 | - |
dc.citation.endPage | 1061 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.subject.keywordAuthor | crack control design | - |
dc.subject.keywordAuthor | RC wall | - |
dc.subject.keywordAuthor | drying shrinkage | - |
dc.subject.keywordAuthor | restraint ratio | - |
dc.subject.keywordAuthor | restraint tensile strain | - |
dc.identifier.url | https://onlinelibrary.wiley.com/doi/10.1002/tal.732 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.