Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Simple Isocratic HPLC Method for the Simultaneous Determination of Sinensetin, Eupatorin, and 30-hydroxy-5,6,7,4'-tetramethoxyflavone in Orthosiphon stamineus Extracts

Full metadata record
DC Field Value Language
dc.contributor.authorMun Fei Yam-
dc.contributor.authorElsnoussi Ali Hussin Mohamed-
dc.contributor.authorLee Fung Ang-
dc.contributor.authorLi Pei-
dc.contributor.authorYusrida Darwis-
dc.contributor.authorRoziahanim Mahmud-
dc.contributor.authorMohd. Zaini Asmawi-
dc.contributor.authorRusliza Basir-
dc.contributor.authorMariam Ahmad-
dc.contributor.authorYoo, Hye Hyun-
dc.contributor.authorKIM DONG HYUN-
dc.contributor.authorChung, Hye Jin-
dc.date.accessioned2021-06-23T08:53:00Z-
dc.date.available2021-06-23T08:53:00Z-
dc.date.issued2012-06-
dc.identifier.issn2005-2901-
dc.identifier.issn2093-8152-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/35045-
dc.description.abstractOrthosiphon stamineus extracts contain three flavonoids (3’-hydroxy-5, 6, 7, 4’-tetramethoxyflavone, sinensetin, and eupatorin) as bioactive substances. Previous reported high performance liquid chromatography- ultraviolet (HPLC-UV) methods for the determination of these flavonoids have several disadvantages, including unsatisfactory separation times and not being well validated according to International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) standard guidelines. A rapid, specific reversed-phase HPLC method with isocratic elution of acetonitrile: isopropyl alcohol: 20 mM phosphate buffer (NaH2-PO4) (30:15:55, v/v) (pH 3.5) at a flow-rate of 1 ml/minute, a column temperature of 25_C, and ultraviolet (UV) detection at 340 nm was developed. The method was validated and applied for quantification of different types of O stamineus extracts and fractions. The method allowed simultaneous determination of 3’-hydroxy-5,6,7,4’- tetramethoxyflavone, sinensetin, and eupatorin in the concentration range of 0.03052 e250 mg/ml. The limits of detection and quantification, respectively, were 0.0076 and 0.061 mg/ml for 3’-hydroxy-5,6,7,4’-tetramethoxyflavone, 0.0153 and 0.122 mg/ml for sinensetin and 0.0305 and 0.122 mg/ml for eupatorin. The percent relative standard deviation (% RSD) values for intraday were 0.048e0.368, 0.025e0.135, and 0.05e0.476 for 3’-hydroxy-5,6,7,4’-tetramethoxyflavone, sinensetin, and eupatorin, respectively, and those for intraday precision were 0.333e1.688, 0.722e1.055, and 0.548e1.819, respectively. The accuracy for intraday were 91.25%e103.38%, 94.32%e109.56%, and 92.85%e109.70% for 30-hydroxy-5,6,7,40-tetramethoxyflavone, sinensetin, and eupatorin, respectively, and those for interday accuracy were 97.49%e103.92%, 103.58% e104.57%, and 103.9%e105.33%, respectively. The method was found to be simple, accurate and precise and is recommended for routine quality control analysis of O stamineus extract containing the three flavonoids as the principle components in the extract.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisher사단법인약침학회-
dc.titleA Simple Isocratic HPLC Method for the Simultaneous Determination of Sinensetin, Eupatorin, and 30-hydroxy-5,6,7,4'-tetramethoxyflavone in Orthosiphon stamineus Extracts-
dc.typeArticle-
dc.identifier.doi10.1016/j.jams.2012.05.005-
dc.identifier.scopusid2-s2.0-84865200457-
dc.identifier.bibliographicCitationJournal of acupuncture and meridian studies, v.5, no.4, pp 176 - 182-
dc.citation.titleJournal of acupuncture and meridian studies-
dc.citation.volume5-
dc.citation.number4-
dc.citation.startPage176-
dc.citation.endPage182-
dc.identifier.kciidART001686357-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskciCandi-
dc.subject.keywordAuthor3' -hydroxy-5-
dc.subject.keywordAuthor6-
dc.subject.keywordAuthor7-
dc.subject.keywordAuthor4'- tetramethoxyflavone-
dc.subject.keywordAuthoreupatorin-
dc.subject.keywordAuthorflavonoids-
dc.subject.keywordAuthorO stamineus-
dc.subject.keywordAuthorHPLC-
dc.subject.keywordAuthorsinensetin-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S2005290112000787?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF PHARMACY > DEPARTMENT OF PHARMACY > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hye Hyun photo

Yoo, Hye Hyun
COLLEGE OF PHARMACY (DEPARTMENT OF PHARMACY)
Read more

Altmetrics

Total Views & Downloads

BROWSE