Development and Structural Assessment of Joints of Permanent Uni-Wall System and Floor Systems in Substructure

Full metadata record
DC Field Value Language
dc.contributor.author천성철-
dc.contributor.author김승훈-
dc.contributor.author노삼영-
dc.contributor.author김갑수-
dc.contributor.author한범석-
dc.date.accessioned2021-06-23T09:06:39Z-
dc.date.available2021-06-23T09:06:39Z-
dc.date.created2021-01-22-
dc.date.issued2012-04-
dc.identifier.issn1598-2033-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/35766-
dc.description.abstractRecently the Permanent Uni-wall System (PUS) has been developed which improved the disadvantage of the Cast-In-Place Concrete Pile (CIP) and could be used as permanent retaining wall. In this study, joints between PUS and floor systems were developed. From analyses of the characteristics of design and construction of PUS, shear friction reinforcements with couplers were adopted for shear design of the joints. Twelve types of joints were developed which were classified according to the types of floor structures, wale, and piles of PUS. Two typical joints were tested and the joints showed satisfactory behaviors on the points of shear strength, stiffness, and serviceability. Especially the shear strengths were much higher than the design strengths due to the shear keys which were by-products in splicing shear reinforcements. However, the shear strength of the joint is recommended to be designed by only shear friction reinforcement because shear key is not reliable and too brittle.-
dc.language영어-
dc.language.isoen-
dc.publisher한국건축시공학회-
dc.titleDevelopment and Structural Assessment of Joints of Permanent Uni-Wall System and Floor Systems in Substructure-
dc.typeArticle-
dc.contributor.affiliatedAuthor노삼영-
dc.identifier.doi10.5345/JKIBC.2012.12.2.230-
dc.identifier.bibliographicCitation한국건축시공학회지, v.12, no.2, pp.230 - 242-
dc.relation.isPartOf한국건축시공학회지-
dc.citation.title한국건축시공학회지-
dc.citation.volume12-
dc.citation.number2-
dc.citation.startPage230-
dc.citation.endPage242-
dc.type.rimsART-
dc.identifier.kciidART001652787-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorCIP-
dc.subject.keywordAuthoruni-wall method-
dc.subject.keywordAuthorretaining wall-
dc.subject.keywordAuthorshear friction-
dc.subject.keywordAuthorwall-floor joint-
dc.identifier.urlhttps://kiss.kstudy.com/thesis/thesis-view.asp?key=3439162-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Noh, Sam Young photo

Noh, Sam Young
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE