석고보드 건식벽체를 이용한 가변형 공동주택의 전과정 CO_2 배출량 및 경제성 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 하성균 | - |
dc.contributor.author | 태성호 | - |
dc.contributor.author | 신성우 | - |
dc.contributor.author | 김경래 | - |
dc.contributor.author | 이종선 | - |
dc.contributor.author | 한상현 | - |
dc.contributor.author | 이진원 | - |
dc.date.accessioned | 2021-06-23T11:38:49Z | - |
dc.date.available | 2021-06-23T11:38:49Z | - |
dc.date.issued | 2011-10 | - |
dc.identifier.issn | 1226-9107 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/38807 | - |
dc.description.abstract | Recently driven by the ease of remodeling and increase of lifespan and performances required of apartment houses, demands for plaster board drywall with outstanding flexibility are growing, and the importance of their assessment of environmental load is rising. In this study, CO_2 generated during the life cycle of a building(LCCO_2) and its economic efficiency were evaluated for the assessment of the environmental load and cost of buildings that used plaster board drywall. Typical concrete bearing wall structure for apartment building was set as case 1, and comparison subjects were developed as case 2, case 3 and case 4 based on the ratio of plaster board drywall on top of case 1. Structural safety of each building to be assessed and the legal incentives by the use of variable type wall were considered. In addition, both for life cycle CO_2 emission and economic efficiency, life cycle assessments were conducted by stages including construction stage, operation/maintenance stage and demolition/waste stage. A set of data including construction material quantity, amount of energy usage, repair rate and repair period etc which are required in each stage of assessment were utilized for both CO_2 assessment and economic efficiency. As a result, in case of flat-type, the life cycle CO_2 reduction rates of cases 2, 3 and 4 compare to case1 were 1.0%, 4.5% and 5.4% respectively, and in the assessment of cost, the reduction rates compare to case1 were -0.01%, 5.8% and 6.0% respectively. | - |
dc.format.extent | 8 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 대한건축학회 | - |
dc.title | 석고보드 건식벽체를 이용한 가변형 공동주택의 전과정 CO_2 배출량 및 경제성 평가 | - |
dc.title.alternative | Assessment for Life Cycle CO_2 Emission and Economic Efficiency of Flexible Apartment Buildings Using Plaster Board Drywall | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 대한건축학회논문집 구조계, v.27, no.10, pp 145 - 152 | - |
dc.citation.title | 대한건축학회논문집 구조계 | - |
dc.citation.volume | 27 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 145 | - |
dc.citation.endPage | 152 | - |
dc.identifier.kciid | ART001598310 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Plaster Board Drywall | - |
dc.subject.keywordAuthor | Flexible Apartment Building | - |
dc.subject.keywordAuthor | Life Cycle | - |
dc.subject.keywordAuthor | CO_2 Emission | - |
dc.subject.keywordAuthor | Economic Efficiency | - |
dc.subject.keywordAuthor | 석고보드 건식벽체 | - |
dc.subject.keywordAuthor | 가변형 공동주택 | - |
dc.subject.keywordAuthor | 전과정 | - |
dc.subject.keywordAuthor | 이산화탄소 | - |
dc.subject.keywordAuthor | 경제성 | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01716432 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.