Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

비인장 강연선을 사용한 접합부 일체형 PC 보-기둥 시스템의 휨성능 평가

Full metadata record
DC Field Value Language
dc.contributor.author노삼영-
dc.contributor.author조민주-
dc.contributor.author김형근-
dc.contributor.author정재천-
dc.date.accessioned2021-06-23T12:02:53Z-
dc.date.available2021-06-23T12:02:53Z-
dc.date.issued2011-01-
dc.identifier.issn1226-9107-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/39054-
dc.description.abstractIn this study, a new moment-resisting precast concrete beam and column joint system was developed mainly for the use in underground parking lot in multi-residential building. It has attempted to devise connection details of the joint which will improve workability and provide effective stress transfer mechanism in the region of connection. The characteristics of the joint system is that the upper main reinforcements pass through the flanks of the column and the two pairs of the untensioned wire strands penetrate through the pre-scribed holes located at the upper and lower centers of the PC column. For the evaluation of the performance of this new joint system, two types of the specimens were tested. The first one is to investigate the behavior of beams reinforced by deformed bars and untensioned strands in combination. The reinforcement ratio of the wire strand to the deformend bar was selected as the test parameter. The test results showed that the flexural capacities of all five specimens were sufficient. However when the untensioned strand reinforcement ratio is exceed 43%, the deflection increased considerably. Secondly the behavior of this joint system under the negative bending moment was investigated. Two specimens differentiated by the type of the penetrating reinforcement (deformed bars or wire strands) were tested. The results showed that the both specimens have sufficient flexural capacities and the deflection and ductility was similar to each other. The study concluded that the new PC beam-column joint system has the structural performance satisfying the requirements,only when the reinforcement ratio of the wire strand is limited.-
dc.format.extent8-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한건축학회-
dc.title비인장 강연선을 사용한 접합부 일체형 PC 보-기둥 시스템의 휨성능 평가-
dc.title.alternativeFlexural Performance Assessment of a Joint-Unified PC Beam-Column System using the Untensioned Wire Strand-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation대한건축학회논문집 구조계, v.27, no.01, pp 51 - 58-
dc.citation.title대한건축학회논문집 구조계-
dc.citation.volume27-
dc.citation.number01-
dc.citation.startPage51-
dc.citation.endPage58-
dc.identifier.kciidART001522421-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorPC Beam-column Joint-
dc.subject.keywordAuthorHalf-PC Beam-
dc.subject.keywordAuthorUntensioned Strand-
dc.subject.keywordAuthorDeflection-
dc.subject.keywordAuthorDuctility-
dc.subject.keywordAuthorFlexural Capacity-
dc.subject.keywordAuthorPC 보-기둥 접합부-
dc.subject.keywordAuthor하프 PC 보-
dc.subject.keywordAuthor비인장 강연선-
dc.subject.keywordAuthor처짐-
dc.subject.keywordAuthor연성-
dc.subject.keywordAuthor휨 성능-
dc.identifier.urlhttps://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01592152-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Noh, Sam Young photo

Noh, Sam Young
ERICA 공학대학 (MAJOR IN ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE