Performance Characteristic of the beta-Human Chorionic Gonadotropin Assay on the Access 2 for Its Use in Doping Control
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, Min-Jung | - |
dc.contributor.author | Lee, Hyeim | - |
dc.contributor.author | Shin, Sang Mi | - |
dc.contributor.author | Yoo, Hye Hyun | - |
dc.contributor.author | Kwon, Oh-Seung | - |
dc.contributor.author | Jin, Changbae | - |
dc.contributor.author | Chung, Bong Chul | - |
dc.date.accessioned | 2021-06-23T12:39:46Z | - |
dc.date.available | 2021-06-23T12:39:46Z | - |
dc.date.created | 2021-01-21 | - |
dc.date.issued | 2010-10 | - |
dc.identifier.issn | 0253-2964 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/39456 | - |
dc.description.abstract | The objective of this study was to validate performance characteristics of the Access 2 (Beckman coulter) system for hCG assays for use as a confirmation test for doping control. The Access 2 assay was linear up to 500 IU/L. The correlation coefficient was higher than 0.999, and the sensitivity of the linearity was 0.82. There were no false positive or false negative cases. LOD was 0.59 IU/L. The method was robust when performed by different people. Repeatability and reproducibility were below 7%. We compared reproducibility and recoveries of Access 2 and Elecsys 2010. Access 2 demonstrated higher reproducibility than Elecsys 2010. Recoveries (accuracy) of Access 2 were between 85 and 105%. Recoveries for Elecsys 2010 were between 91 and 104%. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | 대한화학회 | - |
dc.title | Performance Characteristic of the beta-Human Chorionic Gonadotropin Assay on the Access 2 for Its Use in Doping Control | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoo, Hye Hyun | - |
dc.identifier.doi | 10.5012/bkcs.2010.31.10.2889 | - |
dc.identifier.scopusid | 2-s2.0-78049382860 | - |
dc.identifier.wosid | 000288766000022 | - |
dc.identifier.bibliographicCitation | Bulletin of the Korean Chemical Society, v.31, no.10, pp.2889 - 2892 | - |
dc.relation.isPartOf | Bulletin of the Korean Chemical Society | - |
dc.citation.title | Bulletin of the Korean Chemical Society | - |
dc.citation.volume | 31 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 2889 | - |
dc.citation.endPage | 2892 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001526141 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.subject.keywordPlus | TESTOSTERONE | - |
dc.subject.keywordPlus | SPORTS | - |
dc.subject.keywordPlus | MISUSE | - |
dc.subject.keywordAuthor | beta-hCG | - |
dc.subject.keywordAuthor | Access 2 | - |
dc.subject.keywordAuthor | Doping control | - |
dc.subject.keywordAuthor | Method evaluation | - |
dc.subject.keywordAuthor | Confirmation method | - |
dc.identifier.url | http://koreascience.or.kr/article/JAKO201030560144815.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.