Electrocatalytic reduction of hydrogen peroxide by silver particles patterned on single-walled carbon nanotubes
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bui, Minh-Phuong Ngoc | - |
dc.contributor.author | Pham, Xuan-Hung | - |
dc.contributor.author | Nan, Kwi Nam | - |
dc.contributor.author | Li, Cheng Ai | - |
dc.contributor.author | Kim, Yong Shin | - |
dc.contributor.author | Seong, Gi Hun | - |
dc.date.accessioned | 2021-06-23T12:41:12Z | - |
dc.date.available | 2021-06-23T12:41:12Z | - |
dc.date.issued | 2010-09 | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/39538 | - |
dc.description.abstract | Silver particles were patterned on flexible and transparent single-walled carbon nanotube (swcNT) films using the electrochemical deposition method, and these patteinecl silver pat tides were then used as electrodes to detect hydrogen peroxide (H2O2) The sizes and densities of silver particles were tuned by varying the patterned design and the preparation conditions Field emission-scanning election microscopy revealed that the patteinecl silvei particles were homogeneously distributed on the single-walled carbon nanotube films (AgPs-SWCNT), with an average size of 150-200 nm X-ray diffraction patterns revealed lout peaks, col tesponding to a face-centered cubic silver crystal nanostructure The AgPs-SWCNT sensor displayed a linear electrical response to H2O2 concentrations ranging from 0 016mM to 18.085mM The detection limit and the sensitivity of the sensor were 276 mu M and 10 92 mu A mM(-1) mm(-2), respectively Furthermore, the AgPs-SWCNT sensor was resistant to L-ascorbic acid as an interferent, indicating that it was selective for the electro-reclucnon of H2O2 In addition, the developed sensor showed a stable amperometric response to the reduction of H2O2 over an extended period of time (C) 2010 Elsevier B.V All rights reserved | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Elsevier BV | - |
dc.title | Electrocatalytic reduction of hydrogen peroxide by silver particles patterned on single-walled carbon nanotubes | - |
dc.type | Article | - |
dc.publisher.location | 스위스 | - |
dc.identifier.doi | 10.1016/j.snb.2010.06.019 | - |
dc.identifier.scopusid | 2-s2.0-79952573478 | - |
dc.identifier.wosid | 000282726200062 | - |
dc.identifier.bibliographicCitation | Sensors and Actuators, B: Chemical, v.150, no.1, pp 436 - 441 | - |
dc.citation.title | Sensors and Actuators, B: Chemical | - |
dc.citation.volume | 150 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 436 | - |
dc.citation.endPage | 441 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | DIRECT ELECTROCHEMISTRY | - |
dc.subject.keywordPlus | NANOPARTICLES | - |
dc.subject.keywordPlus | BIOSENSOR | - |
dc.subject.keywordPlus | ARRAY | - |
dc.subject.keywordPlus | FILM | - |
dc.subject.keywordPlus | ELECTRODEPOSITION | - |
dc.subject.keywordPlus | NANOCOMPOSITE | - |
dc.subject.keywordPlus | TRANSPARENT | - |
dc.subject.keywordPlus | PLATINUM | - |
dc.subject.keywordPlus | GLUCOSE | - |
dc.subject.keywordAuthor | Single-walled carbon nanotubes | - |
dc.subject.keywordAuthor | Silver particles | - |
dc.subject.keywordAuthor | Hydrogen peroxide | - |
dc.subject.keywordAuthor | Electrochemical deposition | - |
dc.subject.keywordAuthor | Amperometric detection | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S092540051000496X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.