기포제 혼입 단열형 경량모르타르의 물리적 특성 및 압축강도 추정에 관한 기초적 연구Fundamental Study on Estimating Compressive Strength and Physical Characteristic of Heat insulation Lightweight Mortar With Foam Agent
- Other Titles
- Fundamental Study on Estimating Compressive Strength and Physical Characteristic of Heat insulation Lightweight Mortar With Foam Agent
- Authors
- 민태범; 우영제; 이한승
- Issue Date
- Jun-2010
- Publisher
- 한국생태환경건축학회
- Keywords
- Lightweight Foamed Mortar; Forming Agent; Estimating Compressive Strength; Structural concrete; 경량 모르타르; 기포제; 압축강도 추정; 구조용 콘크리트
- Citation
- 한국생태환경건축학회학회논문집, v.10, no.3, pp 89 - 96
- Pages
- 8
- Indexed
- KCI
- Journal Title
- 한국생태환경건축학회학회논문집
- Volume
- 10
- Number
- 3
- Start Page
- 89
- End Page
- 96
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/40261
- ISSN
- 2288-968X
2288-9698
- Abstract
- In comparison with ordinary or heavy-weight concrete, light-weight air void concrete has the good aspects in optimizing super tall structure systems for the process of design considering wind load and seismic load by lightening total dead load of buildings and reducing natural resources used. Light-weight air void concrete has excellent properties of heat and sound insulating due to its high amount porosity of air voids. So, it has been used as partition walls and the floor of Ondol which is the traditional Korean floor heating system. Under the condition of which the supply of light-weight aggregates are limited, the development of light-weight concrete using air voids is highly required in the aspects of reduced manufacturing prices and mass production.
In this study, we investigated the physical properties and thermal behaviors of specimens that applied different mixing ratios of foaming agent to evaluate the possibility of use in the structural elements. We proposed the estimating equation for compressive strength of each mix having different ratio of foaming agent. We also confirmed that the density of cement matrix is decreased as the mixing amount of foaming agent increase up to 0.6% of foaming agent mixing ratio which was observed by SEM. Based on porosity and compressive strength of control mortar without foaming agent, we built the estimating equations of compressive strength for mortars with foaming agent. The upper limit of use in foaming agent is about 0.6% of the binder amount. Each air void is independent, and size of voids range from 50 to 100㎛.
- Files in This Item
-
Go to Link
- Appears in
Collections - COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.