초순수 물(Ultra Pure Water)내 비휘발성 잔류 물질(Nonvolatile Residue, NVR)의 모니터링을 위한 NVR 측정시스템의 개발The Development of Nonvolatile Residue (NVR) Particle Monitoring System in Ultra Pure Water

Other Titles
The Development of Nonvolatile Residue (NVR) Particle Monitoring System in Ultra Pure Water
Authors
정혁안진홍안강호
Issue Date
Mar-2010
Publisher
한국반도체디스플레이기술학회
Keywords
UPW(ultra pure water); Nonvolatile Residue (NVR); RAE(Residue after evaporation)
Citation
반도체디스플레이기술학회지, v.9, no.1, pp 55 - 59
Pages
5
Indexed
KCI
Journal Title
반도체디스플레이기술학회지
Volume
9
Number
1
Start Page
55
End Page
59
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/40314
ISSN
1738-2270
Abstract
In this study, we developed nonvolatile residue (NVR) real-time monitoring system to measure the nonvolatile residue particle in ultra pure water (UPW). This device has a capability of measuring 4 different channels, i.e., 10 nm, 30 nm, 50 nm, and 100 nm. Until now, the light scattering method to detect RAE(residue after evaporation) was the only choice. However, this method can detect RAE larger than ca. 50 nm. In ultra pure water, RAE particles are usually very small and hard to detect with conventional laser scattering devices. To detect very small RAEs, a new system is developed and tested. The system consists of an atomizer that generates RAE particles and a four channel condensation particle counter (CPC). During the several months’ operation in manufacturing line, the system was successfully tested and showed reliable results.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE