유럽 약전과 일본 산업기준 규격 방식에 의한 폴리비닐 알코올 및 덱스트란 함유 하이드로겔의 투습률 비교평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 황마로 | - |
dc.contributor.author | 오동훈 | - |
dc.contributor.author | 이동훈 | - |
dc.contributor.author | 김종오 | - |
dc.contributor.author | 이청훈 | - |
dc.contributor.author | 용철순 | - |
dc.contributor.author | 우종수 | - |
dc.contributor.author | 최한곤 | - |
dc.date.accessioned | 2021-06-23T15:40:25Z | - |
dc.date.available | 2021-06-23T15:40:25Z | - |
dc.date.issued | 2009-04 | - |
dc.identifier.issn | 2093-5552 | - |
dc.identifier.issn | 2093-6214 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/41311 | - |
dc.description.abstract | To compare the water vapor transmission rate (WVTR) of PVA/Dextran blended hydrogel obtained by European Pharmacopiea (EP) and Japanese Industrial Standards 1099 (JIS) method, the hydrogels with various PVA/Dextran rates were prepared and their WVTR values were then checked. As dextran in the hydrogel was increased, the WVTR of hydrogel was increased. The WVTR of hydrogels were 660-1500 and 730−1900g/m2 -day in EP and JIS method, respectively. There were no significant differences between the WVTRs of the hydrogels obtained by EP and those obtained by JIS method. Thus, JIS method was recommended as a WVTR method of hydrogel due to relatively simpler and shorter time. | - |
dc.format.extent | 3 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 한국약제학회 | - |
dc.title | 유럽 약전과 일본 산업기준 규격 방식에 의한 폴리비닐 알코올 및 덱스트란 함유 하이드로겔의 투습률 비교평가 | - |
dc.title.alternative | Comparative evaluation of water vapor transmission rate of PVA/Dextran blended hydrogel using European Pharmacopiea and Japanese Industrial Standards method | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.4333/KPS.2009.39.2.093 | - |
dc.identifier.bibliographicCitation | 약제학회지, v.39, no.2, pp 93 - 95 | - |
dc.citation.title | 약제학회지 | - |
dc.citation.volume | 39 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 93 | - |
dc.citation.endPage | 95 | - |
dc.identifier.kciid | ART001336160 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Water vapor transmission | - |
dc.subject.keywordAuthor | wound dressing | - |
dc.subject.keywordAuthor | hydrogel | - |
dc.subject.keywordAuthor | European Pharmacopiea | - |
dc.subject.keywordAuthor | Japanese Industrial Stand | - |
dc.identifier.url | https://www.koreascience.or.kr/article/JAKO200917639073431.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.