Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reduction of line width and edge roughness by resist reflow process for extreme ultra-violet lithography

Authors
Cho, In WookPark, Joon-MinKim, HyunsuHong, Joo-YooKim, Seong-SueCho, Han-KuOh, Hye-Keun
Issue Date
Apr-2009
Publisher
SPIE
Keywords
22 nm node; Line edge roughness; Line width roughness; Resist reflow process; Surface roughness
Citation
Proceedings of SPIE - The International Society for Optical Engineering, v.7273, pp 1 - 8
Pages
8
Indexed
SCOPUS
Journal Title
Proceedings of SPIE - The International Society for Optical Engineering
Volume
7273
Start Page
1
End Page
8
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/41791
DOI
10.1117/12.814108
ISSN
0277-786X
Abstract
Extreme ultra-violet lithography (EUVL) has been prepared for next generation lithography for several years. We could get sub-22 nm line and space (L/S) pattern using EUVL, but there are still some problems such as roughness, sensitivity, and resolution. According to 2007 ITRS roadmap, line edge roughness (LER) has to be below 1.9 nm to get a 22 nm node, but it is too difficult to control line width roughness (LWR) because line width is determined by not only the post exposure bake (PEB) time, temperature and acid diffusion length, but also the component and size of the resist. A new method is suggested to reduce the roughness. The surface roughness can be smoothed by applying the resist reflow process (RRP) for the developed resist. We made resist profile which has surface roughness by applying exposure, PEB and development process for line and space pattern. The surface roughness is calculated by changing parameters such as the protected ratio of resin. The PEB time is also varied. We compared difference between 1:1 L/S and 1:3 L/S pattern for 22 nm. Developed resist baked above the glass transition temperature will flow and the surface will be smoothed. As a result, LER and LWR will be much smaller after RRP. The result shows that the decreasing ratio of LER due to RRP is larger when initial LER is large. We believe that current ∼ 5 nm LWR can be smoothed to ∼ 1 nm by using RRP after develop. ©2009 SPIE.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY > DEPARTMENT OF APPLIED PHYSICS > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Joo yoo photo

Hong, Joo yoo
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY (DEPARTMENT OF APPLIED PHYSICS)
Read more

Altmetrics

Total Views & Downloads

BROWSE