Hysteresis 버퍼를 이용한 AC 커플링 커패시터 테스트AC Coupling Capacitor Test using Hysteresis Buffer

Other Titles
AC Coupling Capacitor Test using Hysteresis Buffer
Authors
오정균김민석백상현
Issue Date
Dec-2008
Publisher
한국테스트협회
Keywords
AC Coupling Capacitor; Hysteresis Buffer; Eye Diagram; Bit Error Test
Citation
한국테스트협회논문집, pp 1 - 6
Pages
6
Indexed
DOMESTIC
Journal Title
한국테스트협회논문집
Start Page
1
End Page
6
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/41853
Abstract
Defective capacitors in AC-coupled interconnections can significantly reduce the performance of interconnection channels. Step pulse response is often used to see ISI of a channel. In this paper, the response of a step pulse is proposed to be measured for the purpose of testing AC-coupling capacitors. Hysteresis buffer is used to measure ISI at regular intervals, which is not necessarily same as bit interval. The hysteresis range is iteratively programmed to measure the ISI signals. The result of proposed method showed great capabilities of detecting defective AC-coupling capacitors.