Selective detection of Salmonella typhimurium in the presence of high concentrations of masking bacteria
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lakshmanan, Ramji S. | - |
dc.contributor.author | Guntupalli, Rajesh | - |
dc.contributor.author | Hong, Jong Wook | - |
dc.contributor.author | Kim, Dong-joo | - |
dc.contributor.author | Cheng, Zhongyang | - |
dc.contributor.author | Petrenko, Valerly A. | - |
dc.contributor.author | Barbaree, James M. | - |
dc.contributor.author | Chin, Brayan Allen | - |
dc.date.accessioned | 2021-06-23T16:41:30Z | - |
dc.date.available | 2021-06-23T16:41:30Z | - |
dc.date.created | 2021-02-18 | - |
dc.date.issued | 2008-12 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/41889 | - |
dc.description.abstract | This article presents the results of an investigation into the ability of a magnetoelastic biosensor to detect Salmonella typhimurium, with high specificity, even in the presence of high concentrations of masking bacteria. Magnetoelastic biosensors are mass sensitive devices comprised of a magnetoelastic material that serves as the transducer and bacteriophage as the bio-recognition element. The sensors were tested individually with several different genus bacteria (Salmonella typhimurium, Salmonella entertidis, Escherichia coli O157:H7 and Listeria monocytogenes) to compare the bioprobe's affinity towards species other than the target analyte. The effect of the presence of one masking bacteria (E. coli) and two masking bacteria (E. coli and L. monocytogenes) in a mixture with S. typhimurium upon the response of the biosensor was studied. It was observed that the response of the sensors followed similar trends; however the sensitivity and the frequency changes were slightly lower for the mixtures. The sensitivity of the sensors exposed to only S. typhimurium was 161 Hz decade -1 and in mixtures with one and two masking bacteria were 131 Hz decade -1 and 127 Hz decade -1, respectively. Binding kinetics studies show that the dissociation constant (K d) and the binding valency (1/n H) samples with only S. typhimurium are 149 cfu mL -1 and 2.49, respectively. © Springer Science+Business Media, LLC 2008. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Springer | - |
dc.title | Selective detection of Salmonella typhimurium in the presence of high concentrations of masking bacteria | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Hong, Jong Wook | - |
dc.identifier.doi | 10.1007/s11694-008-9049-x | - |
dc.identifier.scopusid | 2-s2.0-77953633905 | - |
dc.identifier.bibliographicCitation | Sensing and Instrumentation for Food Quality and Safety, v.2, no.4, pp.234 - 239 | - |
dc.relation.isPartOf | Sensing and Instrumentation for Food Quality and Safety | - |
dc.citation.title | Sensing and Instrumentation for Food Quality and Safety | - |
dc.citation.volume | 2 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 234 | - |
dc.citation.endPage | 239 | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | Bacteriology | - |
dc.subject.keywordPlus | Bacteriophages | - |
dc.subject.keywordPlus | Dissociation | - |
dc.subject.keywordPlus | Escherichia coli | - |
dc.subject.keywordPlus | Frequency response | - |
dc.subject.keywordPlus | Mixtures | - |
dc.subject.keywordPlus | Sensors | - |
dc.subject.keywordPlus | Signal transduction | - |
dc.subject.keywordPlus | Viruses | - |
dc.subject.keywordAuthor | Bacteriophage | - |
dc.subject.keywordAuthor | Biosensor | - |
dc.subject.keywordAuthor | Magnetoelastic | - |
dc.subject.keywordAuthor | Selectivity | - |
dc.identifier.url | https://link.springer.com/article/10.1007/s11694-008-9049-x | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.