Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Real-time immunoassay with a PDMS-glass hybrid microfilter electro-immuno sensing chip using nanogold particles and silver enhancement

Full metadata record
DC Field Value Language
dc.contributor.authorKo, Yong-Jun-
dc.contributor.authorMaeng, Joon-Ho-
dc.contributor.authorAhn, Yoomin-
dc.contributor.authorHwang, Seung-Yong-
dc.contributor.authorCho, Nahm Gyoo-
dc.contributor.authorLee, Seoung-Hwan-
dc.date.accessioned2021-06-23T17:39:32Z-
dc.date.available2021-06-23T17:39:32Z-
dc.date.created2021-01-21-
dc.date.issued2008-05-
dc.identifier.issn0925-4005-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/42449-
dc.description.abstractThis paper presents the development of a PDMS-glass hybrid electro-immunosensing chip for real-time measurement of an antigen-antibody reaction through an electrical signal. Using a microfilter and microbeads, the antigen was easily immobilized in the detection zone where the microelectrodes were located. The immuno-reaction was detected by measuring the electrical resistance between microelectrodes using gold nanoparticles with silver enhancement. An immunoassay test with the developed chip was performed for the antigen of protein A, the specific first antibody of anti-protein A, the nonspecific first antibody of HBsAg monoclonal IgG, and the second antibody anti-rabbit IgG. The electro-immunosensing chip reduced the antigen-antibody reaction time to 10 min, thus reducing the overall assay time to about I h. The electrical resistance varied according to the concentration of the specific first antibody, the detection limit of which was 10 ng/ml. Compared to conventional enzyme-linked immunosorbent assays (ELISAs), the process of performing an immunoassay using the electro-immunosensing chip was relatively simple and required less time to complete. In addition, the electro-immunosensing chip required less sample volume. (C) 2008 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherElsevier BV-
dc.titleReal-time immunoassay with a PDMS-glass hybrid microfilter electro-immuno sensing chip using nanogold particles and silver enhancement-
dc.typeArticle-
dc.contributor.affiliatedAuthorAhn, Yoomin-
dc.contributor.affiliatedAuthorHwang, Seung-Yong-
dc.contributor.affiliatedAuthorCho, Nahm Gyoo-
dc.contributor.affiliatedAuthorLee, Seoung-Hwan-
dc.identifier.doi10.1016/j.snb.2008.01.061-
dc.identifier.scopusid2-s2.0-43749111115-
dc.identifier.wosid000256684200047-
dc.identifier.bibliographicCitationSensors and Actuators, B: Chemical, v.132, no.1, pp.327 - 333-
dc.relation.isPartOfSensors and Actuators, B: Chemical-
dc.citation.titleSensors and Actuators, B: Chemical-
dc.citation.volume132-
dc.citation.number1-
dc.citation.startPage327-
dc.citation.endPage333-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusLINKED-IMMUNOSORBENT-ASSAY-
dc.subject.keywordPlusELECTROCHEMICAL ENZYME-IMMUNOASSAY-
dc.subject.keywordPlusHOMOGENEOUS IMMUNOASSAY-
dc.subject.keywordPlusOPTICAL-DETECTION-
dc.subject.keywordPlusMICROCHIP-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusELISA-
dc.subject.keywordPlusTNT-
dc.subject.keywordAuthorimmunoassay-
dc.subject.keywordAuthorelectro-immunosensing-
dc.subject.keywordAuthormicrofilter-
dc.subject.keywordAuthormicrobead-
dc.subject.keywordAuthornanogold particle-
dc.subject.keywordAuthorsilver enhancement-
dc.subject.keywordAuthorPDMS-glass microbiochip-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0925400508000828?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY > ERICA 의약생명과학과 > 1. Journal Articles
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Seung Yong photo

Hwang, Seung Yong
ERICA 과학기술융합대학 (ERICA 의약생명과학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE