Fast and sensitive trace analysis of malachite green using a surface-enhanced Raman microfluidic sensor
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Sangyeop | - |
dc.contributor.author | Choi, Junghyun | - |
dc.contributor.author | Chen, Lingxin | - |
dc.contributor.author | Park, Byungchoon | - |
dc.contributor.author | Kyong, Jin Burm | - |
dc.contributor.author | Seong, Gi Hun | - |
dc.contributor.author | Choo, Jaebum | - |
dc.contributor.author | Lee, Yeonjung | - |
dc.contributor.author | Shin, Kyung-Hoon | - |
dc.contributor.author | Lee, Eun Kyu | - |
dc.contributor.author | Joo, Sang-Woo | - |
dc.contributor.author | Lee, Kyeong-Hee | - |
dc.date.accessioned | 2021-06-23T19:40:28Z | - |
dc.date.available | 2021-06-23T19:40:28Z | - |
dc.date.issued | 2007-05 | - |
dc.identifier.issn | 0003-2670 | - |
dc.identifier.issn | 1873-4324 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/43710 | - |
dc.description.abstract | A rapid and highly sensitive trace analysis technique for determining malachite green (MG) in a polydimethylsiloxane (PDMS) microfluidic sensor was investigated using surface-enhanced Raman spectroscopy (SERS). A zigzag-shaped PDMS microfluidic channel was fabricated for efficient mixing between MG analytes and aggregated silver colloids. Under the optimal condition of flow velocity, MG molecules were effectively adsorbed onto silver nanoparticles while flowing along the upper and lower zigzag-shaped PDMS channel. A quantitative analysis of MG was performed based on the measured peak height at 1615 cm(-1) in its SERS spectrum. The limit of detection, using the SERS microfluidic sensor, was found to be below the 1-2 ppb level and this low detection limit is comparable to the result of the LC-Mass detection method. In the present study, we introduce a new conceptual detection technology, using a SERS microfluidic sensor, for the highly sensitive trace analysis of MG in water. (c) 2007 Elsevier B.V. All rights reserved. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Elsevier BV | - |
dc.title | Fast and sensitive trace analysis of malachite green using a surface-enhanced Raman microfluidic sensor | - |
dc.type | Article | - |
dc.publisher.location | 네델란드 | - |
dc.identifier.doi | 10.1016/j.aca.2007.03.049 | - |
dc.identifier.scopusid | 2-s2.0-34247122821 | - |
dc.identifier.wosid | 000246321300001 | - |
dc.identifier.bibliographicCitation | Analytica Chimica Acta, v.590, no.2, pp 139 - 144 | - |
dc.citation.title | Analytica Chimica Acta | - |
dc.citation.volume | 590 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 139 | - |
dc.citation.endPage | 144 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.subject.keywordPlus | LEUCOMALACHITE GREEN | - |
dc.subject.keywordPlus | LIQUID-CHROMATOGRAPHY | - |
dc.subject.keywordPlus | QUANTITATIVE-ANALYSIS | - |
dc.subject.keywordPlus | RESONANCE | - |
dc.subject.keywordPlus | RESIDUES | - |
dc.subject.keywordPlus | MUSCLE | - |
dc.subject.keywordPlus | CELL | - |
dc.subject.keywordAuthor | microfluidic sensor | - |
dc.subject.keywordAuthor | malachite green | - |
dc.subject.keywordAuthor | surface-enhanced Raman spectroscopy | - |
dc.subject.keywordAuthor | lab on a chip | - |
dc.subject.keywordAuthor | trace analysis | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0003267007006009?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.