가새를 설치한 조립식 스틸 구조의 반응수정계수 평가Evaluation of R-Factor for Cold-Formed Steel Frames with Shear Panels
- Other Titles
- Evaluation of R-Factor for Cold-Formed Steel Frames with Shear Panels
- Authors
- 이문성; 최영환
- Issue Date
- Nov-2006
- Publisher
- 대한건축학회
- Keywords
- Cold-formed Steel; Performance Evaluation; Response Modification Factor; Cold-formed Steel; Performance Evaluation; Response Modification Factor; 조립식 스틸; 내진성능평가; 반응수정계수
- Citation
- 대한건축학회논문집 구조계, v.22, no.11, pp 115 - 122
- Pages
- 8
- Indexed
- KCI
DOMESTIC
- Journal Title
- 대한건축학회논문집 구조계
- Volume
- 22
- Number
- 11
- Start Page
- 115
- End Page
- 122
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/45138
- ISSN
- 1226-9107
- Abstract
- The purpose of this study is to evaluate the performance of cold-formed steel (CFS) frames with shear panels designed under current U.S. design codes and standards of practice. The response modification factor, R, of the cold-formed steel structural system was examined using the rational approach proposed by Foutch and Wilcoski. The approach is based on the performance evaluation method developed from the SAC project. The target is to achieve a 90% confidence level in satisfying the Collapse Prevention(CP) performance level for a hazard level with 2% probability of being exceeded in 50 years. New values for various parameters were decided for CFS buildings because parameters from SAC project were for steel moment frame buildings.
- Files in This Item
-
Go to Link
- Appears in
Collections - COLLEGE OF ENGINEERING SCIENCES > MAJOR IN ARCHITECTURAL ENGINEERING > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.