Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electric signal detection of a microfilter-based biochip for immunoassay using microbead, nanogold particle, and silver enhancement

Authors
Ko, Yong JunCho, Chul HoMaeng, Joon HoLee, Byung ChulAhn, Yoo MinCho, Nahm GyooLee, Seoung HwanHwang Seung Yong
Issue Date
Dec-2006
Publisher
Trans Tech Publications Ltd.
Keywords
Immunoassay electrical detection; Microfilter-based PDMS-glass biochip; Nanogold particle; Silver enhancement
Citation
Key Engineering Materials, v.326-328, pp 839 - 842
Pages
4
Indexed
SCIE
SCOPUS
Journal Title
Key Engineering Materials
Volume
326-328
Start Page
839
End Page
842
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/45382
DOI
10.4028/www.scientific.net/KEM.326-328.839
ISSN
1013-9826
1662-9795
Abstract
This paper presents a microbiochip which can detect an antigen-antibody reaction through an electrical signal in real time with high sensitivity and low sample volume by using nanogold particle and silver enhancement. A filtration method using the microbead is adopted for sample immobilization. The chip is composed of an inexpensive and biocompatible Polydimethylsiloxane (PDMS) layer and Pyrex glass substrate. Platinum microelectrodes for electric signal detection were fabricated on the substrate and microchannel and pillar-type microfilters were formed in the PDMS layer. Successively introducing polystyrene microbeads precoated with protein A, anti-protein A (which was the first antibody) and the second antibody conjugated with nanogold particles into the microchannel, the resulting antigen-antibody complex was fixed on the bead surface. The injection of silver enhancer increased the size of nanogold particles tagged with the second antibody. As a result, microbeads were connected to each other and formed an electrical bridge between microelectrodes. Resistance measured through the electrodes showed a difference of two orders of magnitude between specific and nonspecific immunoreactions. The developed immunoassay chip reduced the time necessary for an antigen-antibody reaction to 10 min, thus shortening the overall analysis time from 3 hours to 50 min. The immunoassay chip reduces analysis time for clinical diagnoses, is simple, and has high sensitivity.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY > ERICA 의약생명과학과 > 1. Journal Articles
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHO, NAHM GYOO photo

CHO, NAHM GYOO
ERICA 공학대학 (DEPARTMENT OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads