전향보상 전압의 위상 변화를 통한 단독운전 검출 방법의 계통 정상 상태의 성능 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김동욱 | - |
dc.contributor.author | 김성민 | - |
dc.date.accessioned | 2021-06-22T12:23:13Z | - |
dc.date.available | 2021-06-22T12:23:13Z | - |
dc.date.issued | 2018-12 | - |
dc.identifier.issn | 1229-2214 | - |
dc.identifier.issn | 2288-6281 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/6953 | - |
dc.description.abstract | This study proposes a new islanding detection method that uses the phase shift of feed–forward voltage and evaluates the performance of an existing method and the proposed method when the grid frequency changes within the allowable range under steady-state conditions. The investigated existing method, which is slip mode frequency shift (SMS), uses current phase shift to detect islanding. The SMS method supplies reactive current to the grid under this condition, but the proposed method does not generate additional reactive power because it does not depend on the current control loop. The performance in steady-state grid condition is evaluated through simulations and experiments. | - |
dc.format.extent | 8 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 전력전자학회 | - |
dc.title | 전향보상 전압의 위상 변화를 통한 단독운전 검출 방법의 계통 정상 상태의 성능 평가 | - |
dc.title.alternative | Performance Evaluation of Islanding Detection Method by Phase Shifted Feed-Forward Voltage in Steady-State Grid Condition | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.6113/TKPE.2018.23.6.373 | - |
dc.identifier.bibliographicCitation | 전력전자학회 논문지, v.23, no.6, pp 373 - 380 | - |
dc.citation.title | 전력전자학회 논문지 | - |
dc.citation.volume | 23 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 373 | - |
dc.citation.endPage | 380 | - |
dc.identifier.kciid | ART002413278 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Anti-islanding detection | - |
dc.subject.keywordAuthor | Feed-forward voltage | - |
dc.subject.keywordAuthor | Grid connected inverter | - |
dc.subject.keywordAuthor | Grid frequency variation | - |
dc.subject.keywordAuthor | SMS(Slip Mode Frequency Shift) | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07578268 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.