Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Impact of transmission non-uniformity of a wrinkled EUV pellicle for N5 patterning under various illuminations

Full metadata record
DC Field Value Language
dc.contributor.authorKim, In-Seon-
dc.contributor.authorKim, Guk-Jin-
dc.contributor.authorYeung, Michael-
dc.contributor.authorBarouch, Eytan-
dc.contributor.authorOh, Hye-Keun-
dc.date.accessioned2021-06-22T14:02:44Z-
dc.date.available2021-06-22T14:02:44Z-
dc.date.created2021-01-21-
dc.date.issued2017-06-
dc.identifier.issn0167-9317-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/9536-
dc.description.abstractTo solve the defect problem during the exposure process of EUV lithography (EUVL), an EUV pellicle is suggested as a solution. Even though use of an EUV pellicle is considered an essential solution for defect control during the exposure process, it is not ready for application in real commercial processes due to how difficult it is to manufacture. Due to tight requirements for an EUV pellicle, flawless fabrication is impossible and deformations such as a wrinkle would result in serious patterning problems. These deformations lead to critical dimension (CD) non uniformity due to the non-uniform transmission distribution caused by a pellicle wrinkle. In this paper, we discuss the impact of transmission non-uniformity caused by a wrinkled pellicle. When we treat the effects of a wrinkled pellicle, we considered off-axis-illumination, which is a promising resolution enhancement technology. By shrinking the target pattern size down to 7 nm nodes (N7) or 5 nm nodes (N5), a flexible illumination system is required to enhance the resolution ability. With dipole illuminations, resolution is varied by partial coherence and by not only the beam size at the pellicle, but also by the incident angle distribution. For these reasons, a non-uniform intensity distribution caused by a wrinkled pellide is modified with changes in off-axis illumination conditions, including spatial coherence and the aperture shape. For N5 patterning, the CD non-uniformity of 0.2 nm occurs at 1.7% transmission variation (2-pass). However, the intensity distribution is varied under various illumination conditions in spite of the same pellicle conditions. The intensity non-uniformity goes up with increasing spatial coherence. Even though feature conditions of the wrinkled pellicle are the same, the transmission non uniformity is changed with illumination conditions. Thus, the allowable feature conditions of the wrinkled pellicle may be changed. For achieving good CD uniformity, the allowable limit of the pellicle wrinkle is carefully studied because the impact of the wrinkled pellicle varies with the illumination conditions. (C) 2017 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.titleImpact of transmission non-uniformity of a wrinkled EUV pellicle for N5 patterning under various illuminations-
dc.typeArticle-
dc.contributor.affiliatedAuthorOh, Hye-Keun-
dc.identifier.doi10.1016/j.mee.2017.01.031-
dc.identifier.scopusid2-s2.0-85011798284-
dc.identifier.wosid000403997500009-
dc.identifier.bibliographicCitationMICROELECTRONIC ENGINEERING, v.177, pp.35 - 40-
dc.relation.isPartOfMICROELECTRONIC ENGINEERING-
dc.citation.titleMICROELECTRONIC ENGINEERING-
dc.citation.volume177-
dc.citation.startPage35-
dc.citation.endPage40-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordAuthorEUV lithography-
dc.subject.keywordAuthorEUV pellide-
dc.subject.keywordAuthorPellicle-
dc.subject.keywordAuthorPellicle deformation-
dc.subject.keywordAuthorTransmission non-uniformity-
dc.subject.keywordAuthorCD uniformity-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0167931717300400?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY > DEPARTMENT OF APPLIED PHYSICS > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads