Detailed Information

Cited 2 time in webofscience Cited 3 time in scopus
Metadata Downloads

High resolution in vivo 31P-MRS of the liver: potential advantages in the assessment of non-alcoholic fatty liver disease

Authors
Jeon, Min JeongLee, YunjungAhn, SangdooLee, ChulhyunKim, Ok-HeeOh, Byung-ChulYu, UngsikKim, Hyeonjin
Issue Date
Sep-2015
Publisher
SAGE PUBLICATIONS LTD
Keywords
31P magnetic resonance spectroscopy (31P-MRS); non-alcoholic fatty liver disease (NAFLD); diagnosis; phosphorous metabolism; carbon tetrachloride (ccl4) animal model
Citation
ACTA RADIOLOGICA, v.56, no.9, pp.1051 - 1060
Journal Title
ACTA RADIOLOGICA
Volume
56
Number
9
Start Page
1051
End Page
1060
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/10194
DOI
10.1177/0284185114550850
ISSN
0284-1851
Abstract
Background: Biopsy remains the current gold-standard for assessing non-alcoholic fatty liver disease (NAFLD). To develop a non-invasive means of assessing the disease, 31P magnetic resonance spectroscopy (31P-MRS) has been explored, but the severe spectral overlaps and low signal-to-noise-ratio in 31P-MRS spectra at clinical field strength are clearly limiting factors. Purpose: To investigate potential advantages of high resolution in vivo 31P-MRS in assessing NAFLD. Material and Methods: The study was conducted at 9.4T in control and carbon tetrachloride (CCl4)-treated rats. Rats were divided according to histopathologic findings into a control group (n = 15), a non-alcoholic steatohepatitis group (n = 17), and a cirrhosis group (n = 12). Data were presented with different reference peaks that are commonly used for peak normalization such as total phosphorous signal, phosphomonoester + phosphodiester (PME + PDE), and nucleotide triphosphate (NTP). Then, multivariate analyses were performed. Results: In all spectra PME and PDE were well resolved into phosphoethanolamine (PE) and phosphocholine (PC), and into glycerophosphorylethanolamine (GPE) and glycerophosphorylcholine (GPC), respectively. Those MRS measures quantifiable only in highly resolved spectra had higher correlations with histology than those conventional MRS measures such as PME, PDE, and NTP. The optimized partial least-squares discriminant analysis (PLS-DA) model correctly classified 79% (22/28) of the rats in the training set and correctly predicted 69% (11/16) of the rats in the test set. Conclusion: PE, PC, GPE, GPC, and nicotinamide adenine dinucleotide phosphate (NADP) that can be separately quantifiable in highly resolved spectra may further improve the potential efficacy of 31P-MRS in the diagnosis of NAFLD.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의예과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Byung Chul photo

Oh, Byung Chul
College of Medicine (Premedical Course)
Read more

Altmetrics

Total Views & Downloads

BROWSE