Numerical Evaluation of Image Homogeneity, Signal-to-Noise Ratio, and Specific Absorption Rate for Human Brain Imaging at 1.5, 3, 7, 10.5, and 14T in an 8-Channel Transmit/Receive Array

Authors
Cao, ZhipengPark, JoshuaCho, Zang-HeeCollins, Christopher M.
Issue Date
May-2015
Publisher
WILEY-BLACKWELL
Keywords
high-field MRI; FDTD; Bloch simulation; signal-to-noise ratio; RF heating; SAR
Citation
JOURNAL OF MAGNETIC RESONANCE IMAGING, v.41, no.5, pp.1432 - 1439
Journal Title
JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume
41
Number
5
Start Page
1432
End Page
1439
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/10572
DOI
10.1002/jmri.24689
ISSN
1053-1807
Abstract
PurposeTo predict signal-to-noise ratio (SNR) trends and absorbed energy in magnetic resonance imaging (MRI) of the brain up to 14T. Materials and MethodsA human head in an eight-channel transmit/receive coil was simulated with Maxwell and Bloch equations to determine excitation homogeneity with radiofrequency (RF) shimming, image homogeneity, SNR, and absorbed energy in MRI from 1.5 to 14T considering realistic field distributions and relaxation properties. ResultsRF shimming alone achieved a standard deviation in excitation flip angle less than 10 degrees in mid-brain up to 14T, but produced a small region with low excitation on a lower slice. Current reconstruction methods may produce shading artifacts at 14T. SNR increases with a greater-than-linear rate for gradient recalled echo (GRE) sequences having short (2 msec) echo time (TE) and long relaxation time (TR) (approximate to 2.3-fold increase from 7T to 14T), but a less-than-linear rate if TE is 10 msec (approximate to 1.6-fold increase from 7T to 14T). Depending on the sequence, SNR per square root of imaging time may produce a less-than-linear increase with B-0. Whole-head absorbed energy shows a less-than-quadratic increase with B-0 (1.7-fold increase from 7T to 14T). ConclusionNumerical simulations indicate that with proper preparation and precautions, imaging of the human brain at up to 14T could be performed safely, with advantages in SNR. J. Magn. Reson. Imaging 2015;41:1432-1439. (c) 2014 Wiley Periodicals, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE