Detailed Information

Cited 0 time in webofscience Cited 4 time in scopus
Metadata Downloads

Viscosity, micro-leakage, water solubility and absorption in a resin-based temporary filling material

Authors
Han, G.-S.Shim, Y.-S.Choi, Y.-R.Jang, S.-O.
Issue Date
2015
Publisher
Indian Society for Education and Environment
Keywords
Micro leakage; Viscosity; Water absorption; Water solubility
Citation
Indian Journal of Science and Technology, v.8, no.25
Journal Title
Indian Journal of Science and Technology
Volume
8
Number
25
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/10946
DOI
10.17485/ijst/2015/v8i25/80262
ISSN
0974-6846
Abstract
The purpose of this study is to examine viscosity, micro-leakage, water solubility and absorption by using various lines of the resin-based temporary filling materials that have flow-ability. The experimental group included 3 types such as Denkist, Korea), Once-fil flow (Mediclus, Korea), Temp-it flow (Spident, Korea). The control group was used composite resin (FiltekTM bulk fill, 3M, USA). Four groups by 5 pieces were classified by using the bovine tooth specimens. Viscometer (Wells Brookfield Cone/Plate, USA) was used for measuring viscosity. The measurement of micro-leakage was carried out thermo-cycling (Thermocycling, M.S.I Co., Korea) with giving a change in temperature totally 1000 times at 5°C and 55°C. The specimen was penetrated the 2% methylene blue dye solution. The water solubility and absorption were gauged by using a precision scale (XS105, Mettler-toledo Inc., Germany). The following results were obtained. The viscosity in Filtek was the highest. Once-fil flow and Temp-it flow showed viscosity at a similar level. The viscosity in Quicks flow was the lowest, thereby having shown significant difference from other materials. Filtek had none with 0 in micro-leakage score, thereby having shown statistically significant difference from 3 groups. As for water absorption, the Temp-it flow group came to 58.96 (μg/mm3 ± 1.63), thereby having indicated the largest water absorption. However, the significant difference wasn't shown in the remaining groups. In terms of solubility, the Quicks flow group amounted to 8.33 μg/mm3 ± 0.32, thereby having shown the largest solubility. The significant difference wasn't shown in the remaining groups. In conclusion, the resin-based temporary filling materials, which were used in the experiment, couldn't be confirmed the material-based difference in viscosity, micro-leakage, water solubility and absorption.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 치위생학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Gyeong Soon photo

Han, Gyeong Soon
Health Science (Dept.of Dental Hygiene)
Read more

Altmetrics

Total Views & Downloads

BROWSE