Detailed Information

Cited 6 time in webofscience Cited 7 time in scopus
Metadata Downloads

Morphologic Changes in Trabecular Meshwork after Patterned and Argon Laser Trabeculoplasty in Cats

Authors
Lee, Jong YeonHa, Seung YeonPaik, Hae JungKwon, Kun-YoungKim, Yong Yeon
Issue Date
Sep-2014
Publisher
TAYLOR & FRANCIS INC
Keywords
Cat; glaucoma; laser trabeculoplasty; scanning electron microscopy; trabecular meshwork
Citation
CURRENT EYE RESEARCH, v.39, no.9, pp.908 - 916
Journal Title
CURRENT EYE RESEARCH
Volume
39
Number
9
Start Page
908
End Page
916
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/12325
DOI
10.3109/02713683.2014.884596
ISSN
0271-3683
Abstract
Purpose: Patterned laser trabeculoplasty (PLT) was introduced as it claimed to cause less thermal damage and provide more uniform coverage of the trabecular meshwork than argon laser trabeculoplasty (ALT). The objective of this study was to investigate morphologic changes in the trabecular meshwork after PLT or ALT in cats. Materials and Methods: We performed ALT in the right eyes and PLT in the left eyes of 6 domestic cats. A seventh cat was assigned as a control. Two ranges of laser energy were used for PLT: supra-threshold energy of 400-450 mW in 3 cats and sub-threshold energy of 250 to 350 mW in 3 cats. Specimens were obtained at 1, 4 and 9 weeks after treatment. Structural changes in the trabecular meshwork were evaluated by light microscopy and scanning electron microscopy. Results: The trabecular meshwork after supra-threshold PLT revealed coagulative damage such as a crater-like lesion with disruption of trabecular beams in early period and extensive membranous obliteration in the late period (at 4 and 9 weeks after treatment), which were comparable to tissue changes after ALT. Sub-threshold PLT resulted in thinning of the uveal meshwork and denudation of trabecular endothelial cells whereas it did not disrupt trabecular beams. Nevertheless, following sub-threshold PLT, partial membranous coverages were observed in the trabecular meshwork in the late period. Conclusions: When used at sub-threshold power, PLT caused less thermal damage to the trabecular meshwork than ALT. However, it did not effectively prevent late scarring of the trabecular meshwork in cats.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의예과 > 1. Journal Articles
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jong Yeon photo

Lee, Jong Yeon
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE