Detailed Information

Cited 27 time in webofscience Cited 28 time in scopus
Metadata Downloads

Liquid crystal-based detection of thrombin coupled to interactions between a polyelectrolyte and a phospholipid monolayer

Authors
Zhang, MinminJang, Chang-Hyun
Issue Date
15-Jun-2014
Publisher
ACADEMIC PRESS INC ELSEVIER SCIENCE
Keywords
Liquid crystals; Orientational transition; Detection; Thrombin; Poly-L-arginine
Citation
ANALYTICAL BIOCHEMISTRY, v.455, pp.13 - 19
Journal Title
ANALYTICAL BIOCHEMISTRY
Volume
455
Start Page
13
End Page
19
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/12534
DOI
10.1016/j.ab.2014.03.018
ISSN
0003-2697
Abstract
Herein, we describe a real-time, label-free biosensing strategy for thrombin detection that uses the orientational properties of nematic liquid crystals (LCs) and the interactions between a polyelectrolyte and a phospholipid monolayer. The imaging principle is based on the disruption of the orientation of 4-cyano-4'-pentylbiphenyl by reorganized 1,2-dioleoyl-sn-glycero-3-phospho-rac-(1-glycerol) sodium salt (DOPG) at the aqueous/LC interface. Positively charged, multiple arginine peptides (poly-L-arginine hydrochloride) interacted with negatively charged DOPG at the aqueous/LC interface, which caused reorganization of the phospholipid layer and induced an orientational transition of LCs from a homeotropic to a planar state. As a result, a dark to bright shift in the optical response was observed. Thrombin cleaves poly-L-arginine hydrochloride into peptides. Thus, when thrombin was added, the optical signals generated by the LCs reverted from bright to dark because of the weakened ability of the fragments to induce electrostatic interactions. The limit of detection of the LC-based sensor was 0.25 ng/mL (6.7 pM) thrombin, and the sensor was fully reusable. The detection limit of our LC-based interface sensor is 600 times lower than that of a previously reported enzyme-linked aptamer assay for the detection of thrombin. Thus, we have established a new, simple thrombin biosensor with high sensitivity and low interference. (C) 2014 Elsevier Inc. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 나노화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Chang Hyun photo

Jang, Chang Hyun
BioNano Technology (Department of Chemistry)
Read more

Altmetrics

Total Views & Downloads

BROWSE