Detailed Information

Cited 1 time in webofscience Cited 2 time in scopus
Metadata Downloads

Measurement of RBC agglutination with microscopic cell image analysis in a microchannel chip

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Chi Hyun-
dc.contributor.authorKim, Ju Yeon-
dc.contributor.authorNyeck, Agnes E.-
dc.contributor.authorLim, Chae Seung-
dc.contributor.authorHur, Dae Sung-
dc.contributor.authorChung, Chanil-
dc.contributor.authorChang, Jun Keun-
dc.contributor.authorAn, Seong Soo A.-
dc.contributor.authorShin, Sehyun-
dc.date.available2020-02-28T21:45:04Z-
dc.date.created2020-02-06-
dc.date.issued2014-01-
dc.identifier.issn1386-0291-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/13980-
dc.description.abstractSince Landsteiner's discovery of ABO blood groups, RBC agglutination has been one of the most important immunohematologic techniques for ABO and RhD blood groupings. The conventional RBC agglutination grading system for RhD blood typings relies on macroscopic reading, followed by the assignment of a grade ranging from (-) to (4+) to the degree of red blood cells clumping. However, with the new scoring method introduced in this report, microscopically captured cell images of agglutinated RBCs, placed in a microchannel chip, are used for analysis. Indeed, the cell images' pixel number first allows the differentiation of agglutinated and non-agglutinated red blood cells. Finally, the ratio of agglutinated RBCs per total RBC counts (CRAT) from 90 captured images is then calculated. During the trial, it was observed that the agglutinated group's CRAT was significantly higher (3.77-0.003) than that of the normal control (0). Based on these facts, it was established that the microchannel method was more suitable for the discrimination between agglutinated RBCs and non-agglutinated RhD negative, and thus more reliable for the grading of RBCs agglutination than the conventional method.-
dc.language영어-
dc.language.isoen-
dc.publisherIOS PRESS-
dc.relation.isPartOfCLINICAL HEMORHEOLOGY AND MICROCIRCULATION-
dc.titleMeasurement of RBC agglutination with microscopic cell image analysis in a microchannel chip-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000332245300007-
dc.identifier.doi10.3233/CH-131673-
dc.identifier.bibliographicCitationCLINICAL HEMORHEOLOGY AND MICROCIRCULATION, v.56, no.1, pp.67 - 74-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-84895809661-
dc.citation.endPage74-
dc.citation.startPage67-
dc.citation.titleCLINICAL HEMORHEOLOGY AND MICROCIRCULATION-
dc.citation.volume56-
dc.citation.number1-
dc.contributor.affiliatedAuthorAn, Seong Soo A.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorAgglutination-
dc.subject.keywordAuthorscoring-
dc.subject.keywordAuthorC-reader-
dc.subject.keywordAuthormicrochannel chip-
dc.subject.keywordAuthorCRAT-
dc.subject.keywordPlusLATEX AGGLUTINATION-
dc.subject.keywordPlusGEL TEST-
dc.subject.keywordPlusANTIGEN-
dc.subject.keywordPlusCOUNTER-
dc.relation.journalResearchAreaHematology-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryHematology-
dc.relation.journalWebOfScienceCategoryPeripheral Vascular Disease-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 바이오나노학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher An, Seong Soo A. photo

An, Seong Soo A.
BioNano Technology (Department of BioNano Technology)
Read more

Altmetrics

Total Views & Downloads

BROWSE