An Intrafascicular Neural Interface With Enhanced Interconnection for Recording of Peripheral Nerve Signals

Authors
Kang, Yoo NaChou, NamsunJang, Jae-WonByun, DonghakKang, HosungMoon, Dong-JunKim, JungsukKim, Sohee
Issue Date
Jun-2019
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Intrafascicular electrode; neural interface; flexible penetrating microelectrode array (FPMA); flexible interconnection cable; Parylene
Citation
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, v.27, no.6, pp.1312 - 1319
Journal Title
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING
Volume
27
Number
6
Start Page
1312
End Page
1319
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1414
DOI
10.1109/TNSRE.2019.2917916
ISSN
1534-4320
Abstract
For implantable devices, Parylene C (hereafter referred to as Parylene) has shown promising properties such as flexibility, biocompatibility, biostability, and good barrier properties. Parylene-based flexible interconnection cable (FIC) was previously developed to connect a flexible penetrating microelectrode array (FPMA) with a recording system. However, Parylene-based FIC was difficult to handle and prone to damage during the implantation surgery because of its low mechanical strength. To improve the mechanical properties of the FIC, we suggest a mechanically enhanced flexible interconnection cable (enhanced FIC) obtained using a combination of Parylene and polyimide. To investigate the long-term stability of the enhanced FIC, Parylene-only FIC, and enhanced FIC were tested and their mechanical properties were compared under an accelerated aging condition. During the course of six months of soaking, the maximum strength of the enhanced FIC remained twice as high as that of the Parylene-only FIC throughout the experiment, although the mechanical strength of both FICs decreased over time. To show the capability of the enhanced FIC in the context of nerve signal recording as a part of a neural interfacing device, it was assembled together with the FPMA and custom-made wireless recording electronics. We demonstrated the feasibility of the enhanced FIC in an in vivo application by recording acute nerve signals from canine sciatic nerves.
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jung Suk photo

Kim, Jung Suk
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE