Detailed Information

Cited 16 time in webofscience Cited 16 time in scopus
Metadata Downloads

A Novel Collateral Imaging Method Derived from Time-Resolved Dynamic Contrast-Enhanced MR Angiography in Acute Ischemic Stroke: A Pilot Study

Authors
Roh, H. G.Kim, E. Y.Kim, I. S.Lee, H. J.Park, J. J.Lee, S. B.Choi, J. W.Jeon, Y. S.Park, M.Kim, S. U.Kim, H. J.
Issue Date
Jun-2019
Publisher
AMER SOC NEURORADIOLOGY
Citation
AMERICAN JOURNAL OF NEURORADIOLOGY, v.40, no.6, pp.946 - 953
Journal Title
AMERICAN JOURNAL OF NEURORADIOLOGY
Volume
40
Number
6
Start Page
946
End Page
953
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1455
DOI
10.3174/ajnr.A6068
ISSN
0195-6108
Abstract
BACKGROUND AND PURPOSE: Assessment of the collateral status has been emphasized for appropriate treatment decisions in patients with acute ischemic stroke. The purpose of this study was to introduce a multiphase MRA collateral imaging method (collateral map) derived from time-resolved dynamic contrast-enhanced MRA and to verify the value of the multiphase MRA collateral map in acute ischemic stroke by comparing it with the multiphase collateral imaging method (MRP collateral map) derived from dynamic susceptibility contrast-enhanced MR perfusion. MATERIALS AND METHODS: From a prospectively maintained registry of acute ischemic stroke, MR imaging data of patients with acute ischemic stroke caused by steno-occlusive lesions of the unilateral ICA and/ or the M1 segment of the MCA were analyzed. We generated collateral maps using dynamic signals from dynamic contrast-enhanced MRA and DSC-MRP using a Matlab-based in-house program and graded the collateral scores of the multiphaseMRAcollateralmapand theMRPcollateralmapindependently. Interobserver reliabilities and intermethod agreement between both collateral maps for collateral grading were tested. RESULTS: Seventy-one paired multiphaseMRAand MRP collateral maps from 67 patients were analyzed. The interobserver reliabilities for collateral grading using multiphase MRA or MRP collateral maps were excellent (weighted kappa = 0.964 and 0.956, respectively). The agreement between both collateral maps was also excellent (weighted kappa = 0.884; 95% confidence interval, 0.819-0.949). CONCLUSIONS: We demonstrated that the dynamic signals of dynamic contrast-enhanced MRA could be used to generate multiphase collateral images and showed the possibility of the multiphase MRA collateral map as a useful collateral imaging method in acute ischemic stroke.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE