Detailed Information

Cited 21 time in webofscience Cited 22 time in scopus
Metadata Downloads

Distortion correction in EPI at ultra-high-field MRI using PSF mapping with optimal combination of shift detection dimension

Authors
Oh, Se-HongChung, Jun-YoungIn, Myung-HoZaitsev, MaximKim, Young-BoSpeck, OliverCho, Zang-Hee
Issue Date
Oct-2012
Publisher
WILEY-BLACKWELL
Keywords
echo planar imaging; EPI; point spread function; combined PSF mapping; geometric distortion; distortion correction; PSF-ghost artifact
Citation
MAGNETIC RESONANCE IN MEDICINE, v.68, no.4, pp.1239 - 1246
Journal Title
MAGNETIC RESONANCE IN MEDICINE
Volume
68
Number
4
Start Page
1239
End Page
1246
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/16115
DOI
10.1002/mrm.23317
ISSN
0740-3194
Abstract
Despite its wide use, echo-planar imaging (EPI) suffers from geometric distortions due to off-resonance effects, i.e., strong magnetic field inhomogeneity and susceptibility. This article reports a novel method for correcting the distortions observed in EPI acquired at ultra-high-field such as 7 T. Point spread function (PSF) mapping methods have been proposed for correcting the distortions in EPI. The PSF shift map can be derived either along the nondistorted or the distorted coordinates. Along the nondistorted coordinates more information about compressed areas is present but it is prone to PSF-ghosting artifacts induced by large k-space shift in PSF encoding direction. In contrast, shift maps along the distorted coordinates contain more information in stretched areas and are more robust against PSF-ghosting. In ultra-high-field MRI, an EPI contains both compressed and stretched regions depending on the B0 field inhomogeneity and local susceptibility. In this study, we present a new geometric distortion correction scheme, which selectively applies the shift map with more information content. We propose a PSF-ghost elimination method to generate an artifact-free pixel shift map along nondistorted coordinates. The proposed method can correct the effects of the local magnetic field inhomogeneity induced by the susceptibility effects along with the PSF-ghost artifact cancellation. We have experimentally demonstrated the advantages of the proposed method in EPI data acquisitions in phantom and human brain using 7-T MRI. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
의과대학 > 의예과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Young Bo photo

Kim, Young Bo
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE