Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

외장재 설치 공간의 화재확산 차단에 관한 연구A Study on Block from Spread of Fire of the Exteriors Installation Space

Other Titles
A Study on Block from Spread of Fire of the Exteriors Installation Space
Authors
민세홍윤정은김미숙
Issue Date
2012
Publisher
대한안전경영과학회
Keywords
Stack effect; Exterior fire; Vertical flame.
Citation
대한안전경영과학회지, v.14, no.2, pp.83 - 89
Journal Title
대한안전경영과학회지
Volume
14
Number
2
Start Page
83
End Page
89
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/17172
ISSN
1229-6783
Abstract
In this study, FDS fire simulation experiments and measured wind speed by applying the exterior installation portion for blocking the spread of the fire was investigated. As a result, aluminum composite panels installed in the lower and the upper part of the panel to remove all the lower side, and then the maximum wind speed 0.24 m/s and the upper side 0.58 m/s were measured. In the FDS, the measured wind speed difference air currents are approximately 3.7 times in 12 seconds, the occurrence of 17 seconds early moment wind 2.2 m/s was measured from. Before and after the fire occurred in early of the air velocity about 39 seconds was 3.5 times difference. Such air currents caused by the temperature of the building but also by the building height was found. Turbulent flame of fire by expanding the vertical extent of damage become greatly important factor. Therefore, through the exterior installation portion of the block that can delay the spread of fire is expected that this should be taken.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 설비·소방공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Min, Se Hong photo

Min, Se Hong
Engineering (Department of Building Equipment System&Fire Protection Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE