Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Right triangular prism-shaped poly(Dimethylsiloxane) (PDMS) Microdevice for multiplex PCR employing a single heater

Full metadata record
DC Field Value Language
dc.contributor.authorWu, W.-
dc.contributor.authorTrinh, K.T.L.-
dc.contributor.authorLee, N.Y.-
dc.date.available2020-02-29T09:43:33Z-
dc.date.created2020-02-11-
dc.date.issued2012-
dc.identifier.issn0000-0000-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/17427-
dc.description.abstractWe propose a right triangular prism-shaped microdevice with serpentine microchannels fabricated on its slanted plane, and apply the device for on-chip flow-through PCR employing a single heater. The inclined nature of the qiandu-shaped microdevice enables the formation of a surface temperature gradient along the slanted plane of the microchannel by the use of a single heater. A 409 bp lung cancer biomarker and a plasmid vector targeting a 230 bp gene fragment were simultaneously amplified in less than 30 min on a single microdevice, paving the way for a microscale, multiplex PCR on a single platform with a single heater.-
dc.language영어-
dc.language.isoen-
dc.publisherChemical and Biological Microsystems Society-
dc.relation.isPartOfProceedings of the 16th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2012-
dc.subjectAtmospheric temperature-
dc.subjectMultiplexing-
dc.subjectPrisms-
dc.subjectSerpentine-
dc.subjectThermal gradients-
dc.subjectFlowthrough-
dc.subjectMicro-device-
dc.subjectMultiplex pcr-
dc.subjectRight triangular prism-shape-
dc.subjectSingle heater-
dc.subjectMicrochannels-
dc.titleRight triangular prism-shaped poly(Dimethylsiloxane) (PDMS) Microdevice for multiplex PCR employing a single heater-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.bibliographicCitationProceedings of the 16th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2012, pp.1507 - 1509-
dc.identifier.scopusid2-s2.0-84901746656-
dc.citation.endPage1509-
dc.citation.startPage1507-
dc.citation.titleProceedings of the 16th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2012-
dc.contributor.affiliatedAuthorWu, W.-
dc.contributor.affiliatedAuthorTrinh, K.T.L.-
dc.contributor.affiliatedAuthorLee, N.Y.-
dc.type.docTypeConference Paper-
dc.subject.keywordAuthorFlow-through PCR-
dc.subject.keywordAuthorMultiplex PCR-
dc.subject.keywordAuthorPDMS microdevice-
dc.subject.keywordAuthorRight triangular prism-shape-
dc.subject.keywordAuthorSingle heater-
dc.subject.keywordAuthorThermal gradient-
dc.subject.keywordPlusAtmospheric temperature-
dc.subject.keywordPlusMultiplexing-
dc.subject.keywordPlusPrisms-
dc.subject.keywordPlusSerpentine-
dc.subject.keywordPlusThermal gradients-
dc.subject.keywordPlusFlowthrough-
dc.subject.keywordPlusMicro-device-
dc.subject.keywordPlusMultiplex pcr-
dc.subject.keywordPlusRight triangular prism-shape-
dc.subject.keywordPlusSingle heater-
dc.subject.keywordPlusMicrochannels-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 바이오나노학과 > 1. Journal Articles
산업·환경대학원 > 산업환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Nae Yoon photo

Lee, Nae Yoon
BioNano Technology (Department of BioNano Technology)
Read more

Altmetrics

Total Views & Downloads

BROWSE